Dynacord DMM 4650 Owner's Manual page 42

Digital message manager
Hide thumbs Also See for DMM 4650:
Table of Contents

Advertisement

Sequence Nummer
S 32
Step Command Parameter
1:
Out
D3 set
2:
Sum=
-20 dB
3:
DMM=
-3dB
4:
Start
Ann.
5:
wt
Stop
6:
End
Sequence Nummer
S 33
Step
Command Parameter
1:
Out
A1 set
2:
wt
In A1 High
3:
Out
B4 clr
4:
Out
B2 set
5:
Out
B3 set
6:
Out
A3 set
7.
Sum=
8:
DMM=
-5dB
9:
Count=
0003
10:
Start
A27
11:
wt
Audio
12:
Dly=
012,0s
13:
wt
Delay
14:
if
Count
15:
Jump
16:
Jump
17:.
Dly=
006,0s
18:
wt
Delay
19:
Count=
0003
20:
Dly=
012,0s
21:
wt
Delay
22:
Stert
A 27
23:
wt
Audio
24:
if
Count
25:
End
26:
Jomp
27:
End
Title
"Ansage"
Announcement via recording input DMM 4650 as long as the
key is being pressed (System input -20 dB).
Description: Closing the signaling contact (D3 = announcement
running) switches the audio controls of the sum input to -20 dB
and the controls of the announcement to -3dB. After the correct level
was set once in the operation menu (announcement), the
announcement is made via one of the DMM 4650's recording inputs.
When the message has ended the DMM 4650 returns to the stand-by
mode.
Title
"BZB-ABC"
BZB ABC alarm
Description: Turns the sound reinforcement system's power on
(relay Al) and waits for acknowledgment (input Al = system
ready). When the system is ready, the output B4 (music program
off) is opened and B2, B3 (mandatory reception E, D) is closed.
Closing the signaling contact (A3 = alarm signal running) swit-
Off
ches the audio controls to the alarm signal's priority. The signal
sequence is defined as follows: 1 minute siren interrupted by two
breaks (=5 * 12sec, siren = 330 - 420 Hz), break 30 seconds and
repeating of the signal sequence (total duration 150 sec.); the
utilized alarm preset is A 27 = 12 sec. siren. Afterwards the DMM
4650 returns to the stand-by mode.
17
10
20
Priority
80
Priority
95
42
Stopp trigger
D3 Low >00,1
Stopp trigger
off

Advertisement

Table of Contents
loading

Table of Contents