Sequence Nummer
S 34
Step Command Parameter
1:
Out
A1 set
2:
wt
In A1 High
3:
out
B4 clr
4:
Out
B2 set
5:
Out
B3 set
6:
Out
A3 set
7:
Sum=
Off
8:
DMM=
-5 dB
9:
Start
A 30
10:
wt
Audio
11:
Start
A 31
12:
wt
Audio
13:
Jump
14:
End
Sequence Nummer
S 35
Step Command Parameter
1:
Out
At set
2:
wt
In Al High
3:
Out
B4 clr
4:
Out
B2 set
5:
Out
B3 set
6:
Out
A3 set
7:
Sum=
8:
DMM=
-5dB
9:
Start
A 32
10:
wt
Audio
11:
Start
A 31
12:
wt
Audio
13:
Jump
14:
End
Title
"gen-emgc"
Ship alarm "General Emergency"
Description: Turns the sound reinforeemnet system's power on (relay
Al) and waits for acknowledgment (input Al = system ready). When
the system is ready, the output B4 (music program off) is opened and
B2, B3 (mandatory reception E, D) gets closed. Closing the signaling
contact (A3 = alarm signal running) switches the audio controls to the
alarm signal's priority. The signal sequence is defined as follows: 7
packages 1.5 sec. 800 Hz tone with 1.5 sec. break (A30) followed by a
4.5 sec. tone with 1.5 sec. break (A31). The sequence runs
continuously until it is stopped by a sequence with a higher priority
(e. g. S 20). The control of settings and relay contacts is taken over
by the stop sequence. After the stop sequence ends, the DMM 4650
90
returns to stand-by mode.
Title
"fireship"
Ship alarm "Fire"
Description: Turns the sound reinforcement system's power on
(relay Al) and waits for acknowledgment (input Al = system ready).
When the system is ready, the output B4 (music program off) is
opened and B2, B3 (mandatory reception E, D) is closed.
Closing the signaling contact (A3 = alarm signal running) switches the
audio controls to the alarm signal's priority.
off
The signalsequence is defined as follows: 1 package 1.5 sec.800 Hz
tone with 1.5 see. break (A32) followed by a 4.5 sec. tone with 1.5 sec
break (A31). The sequence runs continuously until it is stopped by a
sequence with a higher priority (e. g. S 20).
The control of settings and relay contacts is taken over by the stop
sequence.When the stop sequence ends, the DMM 4650 returns to
09
stand-by mode.
Priority
95
Priority
95
43
Stopp trigger
off
Stopp trigger
off