Factory Presets; Factory Presets, Defaults; List Of Trigger Signals - Dynacord DMM 4650 Owner's Manual

Digital message manager
Hide thumbs Also See for DMM 4650:
Table of Contents

Advertisement

The installed software v 1.2 provides pre-stored factory presets for sequences, alarms and gongs. Also defined are
basic settings (menu "System setup") as well as input and output lines. For direct use of these presets, installation
examples are to be found on page 31.
Factory settings, defaults
The user can edit these defaults according to individual requirements.
The data of the menus "outputs" "standby" and "sum level" determines the status of the DMM 4650 in stand-by mode
(no sequence running). A running sequence could lead to a modification of the outputs. Upon completion of the
sequence, the outputs are switched back to their previous status (stand-by mode).
Menu
Parameter 1
Contrast
0%
Backlight
50%
Phones
75%
Priority
Prio1 33
Password
Priol 1111
Outputs
all Low (relay open), except B4 = High
Bypass
off (relay open)
Sum Gain
OdB
Attenuation
alarms OdB
Language
German
RS 232
9600 Baud

List of trigger signals

Delay Trigger starts
Input Level
sec.
type
Al
Off
A2
high
>00, 1
dyn
A3
high
>00, 1
dyn
A4
high
>00, 1
dyn
Bl
high
>00, 1
dyn
B2
high
>00, 1
dyn
B3
high
>00,1
dyn
B4
high
>00, 1
dyn
Cl
high
>00, 1
dyn
C2
high
>00,1
dyn
C3
high
>00,1
dyn
C4
high
>00, 1
dyn
Dl
high
>00,1
dyn
D2
Off
D3
high
>00, 1
dyn
D4
high :>00, 1
dyn

FACTORY PRESETS

Parameter 2
Prio2 66
Prio2 2222
gongs OdB
sequence
release, S21 to S25, S31 and S33 to S37 wait for High at At, return messag(
for system ready, upon release the signal output starts
S20
stops each running sequence
S21
start alarm message MOO
S22
start DIN alarm, pulse trigger
S23
start DIN alarm, high = start, low = stop,
S24
start alarm text sequence, high = start, low = stop,
S25
4-tone gong, pulse trigger
S26
Pre-gong (2-tone), pulse trigger
S27
start message M01, pulse trigger
S28
start message M02, pulse trigger
S29
remote recording M01, pulse trigger, first pulse = start, second pulse = stop
S30
remote recording M02, pulse trigger, first pulse = start, second pulse = stop
-S31
start DIN alarm with announcement key at D2, pulse trigger
announcement in S31, high = announcement, low = alarm
S32
start announcement DMM 4650 Mic, high = start, low = stop-
S36
Morse key
Parameter 3
Prio3 99
Prio3 3333
messages OdB
announcements OdB-
utilization
Function (see sequence)
36
Parameter 4

Advertisement

Table of Contents
loading

Table of Contents