Faq's, Hints - Dynacord DMM 4650 Owner's Manual

Digital message manager
Hide thumbs Also See for DMM 4650:
Table of Contents

Advertisement

User questions, hints
This chapter tries to explain some of the DMM 4650's functions that first may seem somewhat surprising for the user and to
provide the amended solution.
Question:
Recording a message is suddenly interrupted by the DMM 4650?
Explanation: a)
An external contact initiated a sequence with a higher priority (e. g. alarm) than the one of current user. This
reaction is necessary and intended, since no user with a priority level 1 or 2 should be able to block the alarm
functions.
Solution: a)
Record the message with the same number (delete? = yes) after the priority sequence ends.
Explanation: b)
Audio memory overrun.
Solution: b)
Deleting message numbers that are no longer needed re-provides memory, or install additional audio memory
(user 3) in case of need.
Explanation: c)
During recording the DMM 4650 has recognized a defect memory address, which is marked as bad and is no l
onger available for future recordings (bad block).
Solution: c)
Start a new recording using the same message number (delete? = yes).
Question:
The message number xx cannot be recorded. The message "access denied" is displayed.
Explanation: a)
The number has been assigned to a user with higher priority. You cannot delete this message.
Solution: a)
Select another message number.
Explanation: b)
This also happens during a remote recording, if the desired sequence for the message mistakenly has been
recorded by the installer, without programming access for users with a lower priority.
Solution: b)
User 3 has to delete this message.
Question:
How can I test a sequence (only user 3), without audio transmission?
Explanation:
The "System setup" > "Bypass" menu provides the possibility to switch the audio bypass relay to direct
connection (input > output) for the duration of the test. This procedure interrupts the audio connection DMM
signals > output; except when the test sequence itself switches off the relay again.
Question:
What happens when the operation voltage of 24 volts drops for several seconds during the transmission of an
alarm sequence?
Solution:
In case one of the factory preset alarm signals (trigger A3, A4, Bl, or B2) was used re-starts the sequence as
long as the alarm button is still pressed.
Question:
Wha t do I ha ve to do when the green PO WER L ED on the front panel blinks ?
Solution:
The flashing LED is caused by the DMM 4650's self-test routine. The LED blinks whenever an error is being
detected. Detailed information on the cause of the error are only available to the service provider (user 3)
(see also on page 29). Enter the user 3's password in the "self-test" menu, write down the displayed error
messages, and using the soft key "quit" you have to delete all errors one by one.
If the LED starts blinking again, this shows that the error is still present. Look for the cause that generates the
problem and try to solve it - otherwise send the appliance to the manufacturer for servicing.