Connections; Control Inputs And Control Outputs Port A - D; General; Control Levels And Currents - Dynacord DMM 4650 Owner's Manual

Digital message manager
Hide thumbs Also See for DMM 4650:
Table of Contents

Advertisement

CONTROL INPUTS AND CONTROL OUTPUTS PORTS A - D

General:

Operation see page 21
(PORTS C, D are optional)
Each of the 4 ports (A, B, C, D) have 4 inputs and 4 outputs and a power source for supplying floating control keys or
contacts.
The inputs and outputs are galvanic insulated from the DMM 4650 and the adjacent control lines. Port A has an
additional fault output (relay contact) which, during normal operation, is always closed.
The DMM 4650 provides port connection through 25-pole sub-D connectors (male).
Pin assignment for ports A, B, C, D:
@ corresponds to A, B, C, D
pin
1
14
2-15
3-16
4-17
5-18
6
19

Control levels and currents:

Power source -Batt. / +Batt. corresponds to a supply voltage of (20V - 31 V) of the DMM 4650. For current limita-
tion (fuse), a PTC resistor (positive temperature coefficient resistor) is provided at the +Batt connection of each
port.

Inputs:

The polarity of the control inputs is random.
L = low corresponds to
H = highcorrespondsto
max. Uinp = 31 V

CONNECTIONS

name
Batt.
Batt.
INP @ 1
INP @2
INP @3
INP @4
Batt.
Batt.
UINP <
5V (0-5V)
UINP > 10V(10-31V)
pin
name
7-20
OUT @1
8-21
OUT @2
9-22
OUT @3
10-23
OUT @4
11
Batt.
24
Batt.
12-25
Fault Out!!Only PORT A
13
+ Batt. (max. 90 mA)
IINP < 1 mA (0-1 mA)
IINP > 1.8mA (1.8-7mA)