Eaton Powerware 9155 User Manual

Eaton Powerware 9155 User Manual

Double-conversion, split-phase, online uninterruptible 8–15 kva power system (ups)
Hide thumbs Also See for Powerware 9155:
Table of Contents

Advertisement

Powerware 9155 UPS
®
8–15 kVA
User's Guide

Advertisement

Table of Contents
loading

Summary of Contents for Eaton Powerware 9155

  • Page 1 Powerware 9155 UPS ® 8–15 kVA User’s Guide...
  • Page 2 Greenlee is a registered trademark of Greenlee Textron. Modbus is a registered trademark of Modicon. ECopyright 2004–2006 Eaton Corporation, Raleigh, NC, USA. All rights reserved. No part of this document may be reproduced in any way without the express written approval of Eaton Corporation.
  • Page 3 89/336/EEC, Council Directive relating to electromagnetic compatibility 92/31/EEC, Amending Directive 89/336/EEC relating to EMC The EC Declaration of Conformity is available upon request for products with a CE mark. For copies of the EC Declaration of Conformity, contact: Eaton Power Quality Oy Koskelontie 13 FIN-02920 Espoo...
  • Page 4: Special Symbols

    Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISK OF ELECTRIC SHOCK - Indicates that a risk of electric shock is present and the associated warning should be observed. CAUTION: REFER TO OPERATOR’S MANUAL - Refer to your operator’s manual for additional information, such as important operating and maintenance instructions.
  • Page 5: Table Of Contents

    ..............® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide...
  • Page 6 ..........® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide...
  • Page 7: Introduction

    With the Powerware 9155, you can safely eliminate the effects of electrical line disturbances and guard the integrity of your systems and equipment. Figure 1 shows the Powerware 9155 UPS and an optional Extended Battery Module (EBM).
  • Page 8 (CAN) Bridge Card provides connectivity for system metering and operational mode control. The parallel system consists of two to three UPSs, each with a parallel CAN Bridge Card, and a parallel tie cabinet. Refer to the Powerware 9155 Parallel UPS (8–15 kVA) User’s Guide for more information.
  • Page 9: Safety Warnings

    Proper disposal of batteries is required. Refer to your local codes for disposal requirements. Never dispose of batteries in a fire. Batteries may explode when exposed to flame. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 10 Une mise au rebut réglementaire des batteries est obligatoire. Consulter les règlements en vigueur dans votre localité. Ne jamais jeter les batteries au feu. L’exposition aux flammes risque de les faire exploser. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 11: Advertencias De Seguridad

    Es necesario desechar las baterías de un modo adecuado. Consulte las normas locales para conocer los requisitos pertinentes. Nunca deseche las baterías en el fuego. Las baterías pueden explotar si se las expone a la llama. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 12 SAFETY WARNINGS ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 13: Ups Setup

    The approximate weights are shown in the following table. Standard Model Floor Loadings (2-High/3-High Cabinets) Maximum Point Loading Distributed Powerware 9155 Weight (lb) (lb/in Loading (lb/ft 2-High UPS 3-High UPS...
  • Page 14: Clearances

    UPS SETUP Clearances The following clearances are recommended for the Powerware 9155 UPS: From Front of Cabinet 36” (91.4 cm) working space From Back of Cabinet 6” (15.2 cm) without a Maintenance Bypass Module (MBM) or Power Distribution Module (PDM) installed; with an MBM/PDM installed,...
  • Page 15 Reinstall the front cover removed in Step 3. Hang the top edge of the cover on the cabinet first, then lower the bottom edge and snap into place. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 16 With the cabinet supported, slowly pull the pallet away from the cabinet (see Figure 5). Figure 5. Removing the Pallet Roll the cabinet to the desired location. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 17: Selecting An Installation Option

    UPS SETUP Selecting an Installation Option You are now ready to install the Powerware 9155 UPS. Select one of the following installation options according to your UPS configuration: UPS Configuration Installation Chapter UPS only Chapter 4, “UPS Only Installation” on page 13 UPS with an optional input isolation Chapter 5, “Input Isolation Transformer Installation”...
  • Page 18 UPS SETUP ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 19: Ups Only Installation

    NOTE To accommodate the feature of easy system expandability, it is recommended that initial installation of the Powerware 9155 UPS contain wiring to support the maximum capacity of the UPS cabinet. Switch off utility power to the distribution point where the UPS will be connected.
  • Page 20 See Table 1 for specifications and Figure 7 for a detailed view of the UPS terminal block. Replace the UPS wiring access cover. Continue to “Stabilizing the Cabinet” on page 43 to complete the UPS installation. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 21: Ups Terminal Block Wiring

    AWG size than shown in this table because of temperature, number of conductors in the conduit, or long service runs. Follow local requirements. 2 2A Input Output Figure 7. UPS Terminal Block ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 22 UPS ONLY INSTALLATION Figure 8. UPS Only Wiring Diagram ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 23: Input Isolation Transformer Installation

    NOTE To accommodate the feature of easy system expandability, it is recommended that initial installation of the Powerware 9155 UPS contain wiring to support the maximum capacity of the UPS cabinet. Switch off utility power to the distribution point where the UPS will be connected.
  • Page 24 11. Hardwire the input, output, and ground terminations for the input isolation transformer. See Table 2 for specifications and Figure 10 for a detailed view of the input isolation transformer terminal block. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 25 * Use only 75°C-rated copper wire. Minimum wire size is based on 120/208 full load ratings applied to NEC Code Table 310-16. Code may require a larger AWG size than shown in this table because of temperature, number of conductors in the conduit, or long service runs. Follow local requirements. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 26 Greenlee punch or similar device (see Figure 10 on page 19). 16. Install the supplied edge grommet in the top of the input isolation transformer wiring cover. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 27 Insert the supplied nylon bushing inside the wiring access hole. 19. Continue to the following chapter, “UPS-Mounted Bypass Switch Installation,” to complete the installation. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 28: Ups Wiring Diagram

    INPUT ISOLATION TRANSFORMER INSTALLATION Figure 12. UPS with Input Isolation Transformer Wiring Diagram ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 29 INPUT ISOLATION TRANSFORMER INSTALLATION Figure 13. UPS with Input Isolation Transformer and MBM/PDM Wiring Diagram ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 30 INPUT ISOLATION TRANSFORMER INSTALLATION ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 31: Ups-Mounted Bypass Switch Installation

    Remove the lowest top cover screw on each side of the UPS and discard. Lowest Top Cover Screw (one each side) Connecting Plate (8 screws) Figure 14. UPS Rear View (2-High Cabinet Shown) ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 32 UPS electronics unit through an access slot. UPS Electronics Unit MBM/PDM Wiring Access Cover Conduit Landing Plates Figure 16. Installing the MBM or PDM (MBM Shown) ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 33 Continue to the following section, “Wiring the MBM/PDM.” Screws for Top of Module Screws to L-Bracket (three each side) Figure 17. Securing the MBM or PDM (MBM Shown) ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 34: Wiring The Mbm/Pdm

    NOTE To accommodate the feature of easy system expandability, it is recommended that initial installation of the Powerware 9155 UPS contain wiring to support the maximum capacity of the UPS cabinet. Switch off utility power to the distribution point where the UPS will be connected.
  • Page 35 Hardwire the input, output, and ground terminations for the MBM/PDM. See Table 4 for specifications and Figure 19 for a detailed view of the MBM/PDM terminal block. TB10 Figure 19. MBM/PDM Hardwiring (PDM Shown) ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 36 Connect the maintenance bypass (red and black) wires to TB1-2 (the A/B maintenance bypass auxiliary contacts) on the UPS terminal block. Input Output A/B Maintenance Bypass Auxiliary Contacts Figure 20. Wiring from Maintenance Bypass Switch to UPS ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 37 10. Replace the MBM/PDM wiring access cover and conduit landing plate. 11. Continue to “Stabilizing the Cabinet” on page 43 to complete the installation. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 38 UPS-MOUNTED BYPASS SWITCH INSTALLATION Figure 21. UPS with MBM Wiring Diagram ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 39 UPS-MOUNTED BYPASS SWITCH INSTALLATION Figure 22. UPS with PDM Wiring Diagram ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 40 UPS-MOUNTED BYPASS SWITCH INSTALLATION ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 41: Wall-Mounted Bypass Switch Installation

    Width 14.0” (35.6 cm) Depth 6.8” (17.2 cm) Mounting 11.0” (28.0 cm) Centers 20.0” (50.8 cm) Weight 31 lb (14.1 kg) Figure 23. Wall-Mounted Bypass Switch Dimensions ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 42: Wall-Mounted Bypass Switch Setup

    Remove the six screws from the bypass switch front cover and remove the cover (see Figure 24). Remove and discard any packing material from inside the bypass switch. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 43: Wiring The Wall-Mounted Bypass Switch

    NOTE To accommodate the feature of easy system expandability, it is recommended that initial installation of the Powerware 9155 UPS contain wiring to support the maximum capacity of the UPS cabinet. Switch off utility power to the distribution point where the bypass switch cabinet and UPS will be connected.
  • Page 44 See Figure 26 for a detailed view of the terminal strip label. Figure 26. Wall-Mounted Bypass Switch Terminal Strip Wiring ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 45 AWG size than shown in this table because of temperature, number of conductors in the conduit, or long service runs. Follow local requirements. 2 2A Input Output Figure 27. UPS Terminal Block ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 46 Do Not Connect Red and Black Wires To UPS Terminal Block Signal Cable Figure 28. Signal Cable Installation 11. Replace the bypass switch front cover and the UPS wiring access cover. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 47 WALL-MOUNTED BYPASS SWITCH INSTALLATION Figure 29. UPS with Wall-Mounted Bypass Switch Wiring Diagram ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 48 WALL-MOUNTED BYPASS SWITCH INSTALLATION ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 49: Stabilizing The Cabinet

    Chapter 8 Stabilizing the Cabinet NOTE For seismic installations, you MUST order and install a Powerware 9155 UPS seismic kit; do not use the following instructions. NOTE For non-seismic installations, you MUST install the stabilizing bracket on all 3-high cabinets. The stabilizing bracket is optional for 2-high cabinets.
  • Page 50 STABILIZING THE CABINET M4 Screws Figure 31. Stabilizing Bracket with One Cabinet M4 Screws Figure 32. Stabilizing Bracket with Two Cabinets ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 51 STABILIZING THE CABINET M4 Screws Figure 33. Stabilizing Bracket with Three Cabinets ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 52 STABILIZING THE CABINET ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 53: Extended Battery Module Installation

    EBM. Repeat for each additional EBM. EBM Battery Circuit Breaker Rear Ground Strap EBM Battery Connector UPS Battery Connector UPS Battery Circuit Breaker Cable Figure 34. Typical EBM Installation (2-High Cabinets Shown) ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 54 NOTE After UPS startup, ensure maximum battery runtime by configuring the UPS for the correct number of EBMs (see page 64). Front Ground Strap Figure 35. Front Ground Strap Installation (2-High Cabinets Shown) ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 55: Communication

    Signal Input 1 X-Slot Communication Bay #2 Signal Input 2 REPO (normally open) REPO (normally closed) DB-9 Communication Port Relay Output Contacts Figure 36. Communication Options and Control Terminals ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 56: Installing Communication Options And Control Terminals

    With wire cutters, cut either side of the tab and twist down to remove the tab (see Figure 39). ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 57 Be sure the cables fit in the access holes in the covers. Continue to “Operation” on page 57 to start up the UPS. Figure 40. Reinstalling the Front Covers ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 58: Communication Options

    COMMUNICATION Communication Options The Powerware 9155 has serial communication capabilities through the DB-9 communication port or through an X-Slot card in one of the available bays. In addition, the Powerware LanSafe Power Management Software can be installed and used to communicate with the UPS via one of the serial communication connections.
  • Page 59: X-Slot Cards

    USB Card - connects to a USB port on your computer. NOTE The Powerware 9155 does not detect plug-and-play hardware. Before installing the USB Card, set the UPS baud rate to 1200 through the front panel (see Table 9 on page 59).
  • Page 60: Powerware Lansafe Power Management Software

    UPS or power information. If there is a power outage and the Powerware 9155 UPS battery power becomes low, Powerware LanSafe software can automatically shut down your computer system to protect your data before the UPS shutdown occurs.
  • Page 61: Remote Emergency Power-Off

    The relay output contacts must not be connected to any utility connected circuits. Reinforced insulation to the utility is required. The relay output contacts have a maximum rating of 30 Vac/1A and 60 Vdc/2A nominal values. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 62: Programmable Signal Inputs

    If active, the UPS knows that input is fed from the generator. Bypass is disabled; the automatic battery test is disabled. External Transformer This option is not used. Overtemperature ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 63: Operation

    Chapter 11 Operation This chapter contains information on how to use the Powerware 9155, including front panel operation, UPS startup and shutdown, operation of the maintenance bypass switch, and configuring the UPS for Extended Battery Modules (EBMs). Control Panel Functions The UPS has a four-button graphical LCD with backlight.
  • Page 64: Changing The Language

    Display Functions As the default or after 15 minutes of inactivity, the LCD displays the selectable startup screen. The default is the Eaton Powerware logo and can be changed to the Mimic screen in the User Settings menu. The backlit LCD automatically dims after a long period of inactivity. Press any button to restore the screen.
  • Page 65: User Settings

    (see “Programmable Signal Inputs” on page 56) Serial Port Config Port: [X-Slot-1] [X-Slot-2/Serv] 19200 Speed: [19200] [9600] [2400] [1200] Parallel Operation Settings Refer to the Powerware 9155 Parallel UPS (8–15 kVA) User’s Guide. Modem Config Modem Installation <Not Installed> Set Modem Call Events Event #0...
  • Page 66 Site Wiring Fault Notice Enabled/Disabled Enabled Reset Custom Event Settings 0 through 32 Total: 0/32 Auto Output Configuration Enabled/Disabled Enabled for initial startup Disabled after initial startup ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 67: Ups Startup

    UPS with an optional wall-mounted bypass switch “Wall-Mounted Maintenance Bypass Startup” on page 64 Parallel UPS configuration Refer to the Powerware 9155 Parallel UPS (8–15 kVA) User’s Guide Normal Mode Startup To start up the UPS: If you have an optional MBM/PDM or wall-mounted bypass switch, verify that the maintenance bypass switch is in the UPS position (see Figure 45 on page 68 or Figure 48 on page 72).
  • Page 68: Starting The Ups On Battery

    Confirm the selection. Press and hold the button for three seconds, until the UPS stops beeping. The UPS starts in Battery mode within two minutes and supplies battery power to your equipment. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 69: Internal Bypass Startup

    Press the button to select the Go To Normal Mode option. Press the button until the Eaton Powerware logo appears. Maintenance Bypass Startup To start the UPS in maintenance bypass (UPS-mounted operation): Verify that the maintenance bypass switch is in the BYPASS position (see Figure 45 on page 68).
  • Page 70: Wall-Mounted Maintenance Bypass Startup

    * UPS-32 models contain 2 strings; EBM-64 models contain 4 strings. UPS-64 models contain 4 strings; EBM-96 models contain 6 strings. Press the button to save the setting. Press the button until the Eaton Powerware logo appears. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 71: Ups Shutdown

    Switch the UPS battery circuit breaker to the OFF position. The UPS is disconnected from the batteries and is on logic power only. Switch off utility power where the UPS is connected. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 72 OPERATION ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 73: Ups Maintenance

    Check the battery recharge date on the shipping carton label. If the date has expired and the batteries were never recharged, do not use the UPS. Contact your service representative. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 74: When To Replace Batteries

    Bypass Module (MBM) or Power Distribution Module (PDM) and is located on the back of the UPS (see Figure 45). Figure 45. Maintenance Bypass Switch (PDM Shown) ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 75 Figure 46 shows a UPS with a separate battery cabinet and a UPS-mounted bypass switch. UPS-Mounted Bypass Switch Bypass User-Supplied Service Building Load Service Distribution Panel Panel Bypass Service Bypass Service Figure 46. Typical Hardwired Installation with UPS-Mounted Bypass Switch ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 76: Using The Wall-Mounted Bypass Switch

    UPS, this is the appropriate position for UPS maintenance or repair. Disconnects the load from the UPS output power and AC input power, as well as AC input power to the UPS input. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 77 Figure 47 shows a UPS with a separate battery cabinet and a wall-mounted bypass switch. Wall-Mounted Bypass Switch Service Line Building Load Service Distribution Panel Panel Service Line Service Line User-Supplied Figure 47. Typical Hardwired Installation with Wall-Mounted Bypass Switch ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 78 Step 3; otherwise, power to the load may be lost. Turn the maintenance bypass switch to the UPS position to return to Normal mode. The UPS is now powering the load. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 79: Specifications

    PW9155-15-64 3-high: UPS with two battery sections 15 kVA, 13.5 kW Extended Battery Description Module (EBM) PW9155-EBM-64 2-high: two battery sections PW9155-EBM-96 3-high: three battery sections ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 80 EN 55022 Class A (CISPR22 Class A) and IEC 60950; IEC 62040-1-1 Agency Markings cULus, cUL, CE, NOM-NYCE EMC (Class A) IEC 62040-2, FCC Part 15, ICES-003, VCCI ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 81 Efficiency (Minimum) Power Dissipation (BTU/hr) 5582 5582 5582 5582 5582 DC Voltage (Supply) * Input current for the input isolation transformer is 4% higher than for the UPS. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 82 Efficiency (Minimum) Power Dissipation (BTU/hr) 3300 3300 3300 3300 3300 DC Voltage (Supply) * Input current for the input isolation transformer is 4% higher than for the UPS. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 83: Battery Specifications

    15 kVA/13.5 kW 12 kVA/10.8 kW 10 kVA/9 kW 8 kVA/7.2 kW NOTE Battery times are approximate and vary depending on the load configuration and battery charge. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 84 SPECIFICATIONS ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 85: Troubleshooting

    UPS position (or restart the UPS if you do not have a switch). If the condition persists, contact your service representative. Battery test failed The batteries need service. Contact your service representative. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 86: Silencing The Alarm

    Please have the following information ready when you call for service: Model number Serial number Firmware version number Date of failure or problem Symptoms of failure or problem Customer return address and contact information ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 87: Warranty

    ® WARRANTOR: The warrantor for the limited warranties set forth herein is Eaton Electrical Inc., a Delaware Corporation company (“Company”). LIMITED WARRANTY: This limited warranty (this “Warranty”) applies only to the original end-user (the “End-User”) of any Powerware 9150, 9155, 9170+, and FERRUPS 4.3–18 kVA Products (individually and collectively, the “Product”) purchased on or after June 1, 2004 and cannot be...
  • Page 88: Ten-Year Pro-Rated Limited Warranty (Us And Canada)

    Powerware UPS Models: 5115, 5125, 5140, 9104, 9120, 9125, 9155, 9170+, and FERRUPS WARRANTOR: The warrantor for the limited warranties set forth herein is Eaton Electrical Inc., a Delaware Corporation company (“Company”). LIMITED WARRANTY: This pro-rated limited warranty (this “Warranty”) applies only to the original End-User (the “End-User”) of any Powerware 5115, 5125, 5140, 9104, 9120, 9125, 9155, 9170+, and FERRUPS Products (individually and collectively, the “Product”) and cannot be transferred.
  • Page 89 Product for return, credit or exchange unless expressly authorized by Company in writing and delivered FOB Company factory. For comments or questions about this Warranty, write to the Customer Quality Representative, 3301 Spring Forest Road, Raleigh, North Carolina 27616 USA. ® EATON Powerware 9155 UPS (8–15 kVA) User’s Guide 164201553 Rev F www.powerware.com...
  • Page 90: Load Protection Guarantee (Us And Canada)

    Load Protection Guarantee (US and Canada) Powerware UPS Models 3105, 3110, 3115, 5110, 5115, 5125, 9120, 9125, 9150, 9155, 9170+, and FERRUPS GUARANTOR: The Guarantor for the load protection guaranty set forth herein is Eaton Electrical Inc., a Delaware Corporation company (“Company”). LIMITED GUARANTY: This load protection guaranty (this “Guaranty”) applies only to the original End-User (the “End-User”) of any Powerware...

Table of Contents