Default Settings (Option 7)

Select 7 to reset the unit's channel configuration and expert settings to the default settings.
The server configuration settings for IP address, gateway IP address, and netmask remain
unchanged. The specific settings that this option changes are listed below:

Channel 1 and Channel 2 Configuration Defaults

Channel Setting
Baudrate
I/F Mode
Flow
Port number
Connect Mode
Send '+++' in Modem Mode
Show IP addr after 'RING'
Auto increment source port
Hostlist retry counter
Hostlist retry timeout
Start character for serial channel 1
All other parameters

Expert Settings Defaults

Expert Setting
TCP Keepalive time in s
ARP Cache timeout in s
Disable Monitor Mode @ bootup
HTTP Port Number
MTU Size
TCP Re-Transmission Timeout
(500-4000)
Alternate MAC
Ethernet Connection Type
Micro125 User Guide
9: Setup Mode: Advanced Settings
Default Configuration
9600
4C (1 stop bit, no parity, 8 bit, RS-232C)
00 (no flow control)
10001 (channel 1)
10002 (channel 2)
C0 (always accept incoming connection; no active
connection startup)
Enabled
Enabled
Disable
3
250 (msec)
0x0D (CR)
0
Default Configuration
45
600
No
80
0 (resulting in an operational value of 1400)
500 (ms)
Disabled ( for OEM use only)
0 (auto-negotiate)