Quantum Scalar i40 and Scalar i80 User's Guide
The library "not ready" messages include the following, with possible
solutions listed:
Message
Library is not ready
Library is becoming ready
Library is not initialized
Library needs manual
attention
Note: You may not see the "not ready" message in the Web client
until the browser refreshes. Similarly, even if the problem has
been resolved, the "not ready" message will not disappear
from the Web client until the browser refreshes.
Chapter 9: Troubleshooting
Troubleshooting Library "Not Ready" Messages
Resolution
The library is initializing and becoming
ready. Wait for the library to finish
initialization.
Wait for the library to finish
initialization.
Most likely a problem with the robot.
Try the following:
• Check the diagnostic ticket and
follow the resolution steps listed (see
About Diagnostic Tickets
page 244).
• Power cycle the library to clear the
error. If that fails, contact Quantum
Support.
Most likely a problem with the robot or
other component. Try the following:
• Check the diagnostic ticket and
follow the resolution steps listed (see
About Diagnostic Tickets
page 244).
• Power cycle the library to clear the
error. If that fails, contact Quantum
Support.