Exporting Cleaning Cartridges - Quantum Scalar i40 User Manual

Hide thumbs Also See for Scalar i40:
Table of Contents

Advertisement

Exporting Cleaning
Cartridges
Quantum Scalar i40 and Scalar i80 User's Guide
When AutoClean is enabled (at least one cleaning slot has been
configured), you can export one or more cleaning cartridges from
dedicated cleaning slots to the I/E station for removal from the library.
You may need to export expired cleaning cartridges or free up cleaning
slots for data storage.
After exporting cleaning cartridges, you can reduce the number of
configured cleaning slots. The extra slots become available for use as
storage slots. For information on configuring cleaning slots, see
Configuring Cleaning Slots
see
About AutoClean
Note: If your library has zero I/E station slots, you cannot import or
export cleaning media. See
page 63.
Caution: Some host applications may fail import/export operations
when the I/E station contains cartridges that are assigned
to another partition. Move cartridges from the I/E station
as soon as possible to avoid possible conflicts with the
other partitions.
The number of cleaning cartridges you can export is limited to the
number of empty I/E station slots.
You can export cleaning cartridges from either the operator panel or the
Web client.
Operator Panel
1 Select Actions > I/E > Export Cleaning Tape.
2 Use the Up and Down buttons to select a cleaning cartridge to
export.
3 Press Export.
The library moves the selected cleaning cartridge to an I/E station
slot.
Chapter 5: Performing Library Operations
on page 61. For a description of AutoClean,
on page 130.
Configuring I/E Station Slots
Cleaning Tape Drives
on
133