Possible Causes:
1.
The hopper lid has stayed open for more than 3
minutes
SMOKE SMELL COMING BACK INTO THE HOME
Possible Causes:
1.
There is a leak in the vent pipe system.
2.
A gasket on the exhaust blower housing or on the
clean out trap is in bad condition.
AUGER MOTOR STOP FEEDING PELLETS AND COMES BACK ON
Possible Causes:
1.
The auger motor is overheating and tripping the
internal temperature shutoff (thermal protector).
Possible Remedies:
As a security measure, the auger stops turning and feeding pellets as soon
as the hopper lid opens. It will resume normal operation as soon as the
hopper lid is closed. If the hopper lid stays open for more than 3 minutes,
the unit will stop and a code "d" will appear on the control board. Close the
hopper lid. Reset the unit and start it again.
If the lid is properly close the hopper lid switch is defective or misconnected
Possible Remedies:
Inspect all vent pipe connections. This is a pressurized exhaust system. All
vent connector joints must be sealed and fastened in accordance with the
pellet pipe manufacturer's instructions to ensure consistent performance and
avoid smoke and ash spillage.
Inspect the gasket on the exhaust blower housing to make sure it is in good
condition. Make sure that all clean out trap gaskets are in good condition
and all bolts are tight.
Possible Remedies:
Start by emptying the hopper. Then, remove the auger motor by removing
the screws holding the motor to the auger shaft. Once the motor is out,
remove the four screws on the steel plate holding the auger shaft to the
auger housing.
Then, rotate the bottom end of the auger shaft down
towards you until you can pull the shaft down out of the stove. After you
have removed the shaft, inspect it for bent flights, burrs, or broken welds.
Remove any foreign material that might have caused the jam. Also, check
the auger housing for signs of damage such as burrs, rough spots, or grooves
cut into the metal that could have caused a jam. Clean the auger housing
thoroughly to remove all pellet dust. Repeat the process whit the burn pot
auger motor.