2.14. FILLING-UP THE AUGER

When the stove runs out of pellets, it empties the auger housing. In order to start the stove again, you need
to fill the auger to bring pellets to the burn pot for ignition. This process takes approximately 1 minute and a
function has been programmed on the LCD interface. In order to fill the auger, push the auger button. When
that button is pressed, a 3 option window appears:
Figure 24
Auger button options
The FEED AND START button is used when you start the stove after the hopper run out of pellet. The
auger will run during 1 minute then the stove will start automatically an ignition sequence.
The PURGE SCREW button is used to empty the auger at the end of the season, the auger will run
during 4 minutes.
The ADD PELLETS button is used to add more pellet in the burn pot, the auger will run for 20
seconds.

2.15. IF YOUR STOVE RUNS OUT OF PELLETS

If your stove runs out of pellets, the fire goes out and the auger motor and blowers will run until the stove
cools down. This will take a few minutes. After the stove's components stop running, a warning message "NO
FUEL" will appear on the LCD display.
To restart the stove, press the "RESET" button, refill the hopper, and press the
button followed by FEED
AND START button.

2.16. REFUELING

We recommend that you not let the hopper go completely empty. Upon reloading, if the hopper lid stays
open for more than 3 minutes, a warning code ''HOPPER LID OPEN'' will appear on the LCD display. To
restart, press the "RESET" button, and then press the round "ON/OFF" icon on the main status page to start the
unit.
KEEP HOPPER LID CLOSED AT ALL TIMES EXCEPT WHEN REFILLING. THE HOPPER MAY BE FILLED WHILE THE STOVE
IS OPERATING. DO NOT OVERFILL HOPPER.