ANCHOR THE STOVE

The stove must be anchored to the floor with screws. Please use the two holes located on each side of the
pedestal (see figure 9.)
FIGURE 9
Anchor location
1.6.

VENTING

In Canada, we recommend that you use a listed pellet vent that meets the ULC S-609-M89/ORD C441-M90
Standard.
For the United States, we recommend that you use a listed pellet vent that meets the UL-641Standard.
This unit can be vented in an existing factory-built or masonry chimney with the addition of a liner, provided
the chimney is more than 4" in diameter. The liner should be listed and should meet the ULC S-635/640
standard in Canada and the UL-1777 standard in the USA. Refer to the instructions provided by the vent or
chimney manufacturer, especially when passing through a wall, ceiling, or roof.
Your venting system should have at least one foot of vertical rise for each foot of horizontal run. The total
vertical rise should never be less than 3 feet (see Appendix A).
This unit uses a pressurized exhaust system. All vent connector joints must be sealed and fastened. If vented
horizontally, joints should be made gastight. Please consult the pellet pipe manufacturer's instruction to ensure
proper installation and consistent performance to avoid smoke and ash spillage.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
WARNING: INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.