If you are using a wireless wall thermostat or a hand held thermostatic remote control, you can locate the
receiver behind the stove's back panel, on the right end side, just below the terminal block. Most
receivers are already equipped with quick-connect terminals.
connected to the back of the terminal block and connect them directly with the receiver's terminals.
Location of the thermostat is very important to obtain the best comfort and efficiency from your EUROMAX.
The thermostat should be mounted 50 inches from the floor on a wall located 15 to 20 feet from the
stove. You should avoid an installation directly in front of the stove to avoid cycling.(See figure 23)
N.B.: It is possible to change the setting of your unit such that if the thermostat does not call for heat after 45
minutes(lag time), the unit will remain at the lowest heat level (#1) but will not shut down (this is the PILOT
ON mode). The stove will remain at the lowest heat level until the thermostat calls for heat again. In the
other way, it is also possible that the unit shuts down as soon as the thermostat stops calling for heat. This
mode is called "PILOT OFF". If you prefer that your unit runs following one of these logics PILOT ON or PILOT
OFF, you need to change the setting to ALWAYS ON or PILOT OFF. According to your preferences, you can
also be able to set the pilot lag time to 30, 45 or 60 minutes. In order to change the pilot lag time, refer to
the operation tree at the beginning of this section.
NOTE: When in thermostatic mode:
You should not operate the manual control or play with the temperature setting.
YOUR THERMOSTAT SHOULD BE INSTALLED BY AN AUTHORIZED DEALER OR SERVICE PERSON.

2.13. PRE-START-UP CHECK

Remove burn pot, making sure it is clean and none of the air holes are plugged. Clean the firebox, and then
reinstall burn pot. Clean door glass if necessary (a dry cloth or paper towel is usually sufficient). Never use
abrasive cleaners on the glass or door. Check fuel in the hopper, and refill if necessary. Make sure that the
fresh air inlet damper is open.
Figure 23
Thermostat Location
Simply unplug the PC board wires