Technical information
■ When WEB Control administrator rights password is not set (Non-protect
▶
mode)
▶
zConnection method
1) Obtain the IP address and port number (Initial set value = 1024) of the projector and
request for a connection to the projector.
You can obtain both the IP address and the port number from the menu screen of the projector.
IP address
Port number
2) Check the response from the projector
Response data
Data section
"NTCONTROL"
(ASCII string)
Mode: 0 = Non-protect mode
▶
zCommand transmission method
Transmit using the following command formats.
Transmitted data
'0'
0x30
1 byte
Received data
'0'
0x30
1 byte
Error response
"ERR1" Undefined control command
"ERR2" Out of parameter range
"ERR3" Busy state or no-acceptable period
"ERR4" Timeout or no-acceptable period
"ERR5" Wrong data length
"ERRA" Password mismatch
112 - ENGLISH
Obtain from MAIN MENU → [NETWORK] → [NETWORK STATUS]
Obtain from MAIN MENU → [NETWORK] → [NETWORK CONTROL] → [COMMAND
PORT]
9 bytes
Header
1 byte
Header
1 byte
Error message
4 bytes
Blank
' '
0x20
1 byte
'0'
Control command
0x30
Undefined length
'0'
Control command
0x30
Undefined length
Termination
Mode
'0'
0x30
1 byte
Data section
(ASCII string)
Data section
(ASCII string)
Termination symbol
symbol
(CR)
0x0d
1 byte
Termination
symbol
(CR)
0x0d
1 byte
Termination
symbol
(CR)
0x0d
1 byte
(CR)
0x0d
1 byte