Road condition and examples of carburetor setting
Conditions
Under 10 °C
(50 °F)
Parts
(Winter)
Main jet
#140
Jet needle
NBKF-2
Pilot jet
#45
Pilot air screw
Zero
NOTE:
Optimum pilot air screw setting can be obtained by adding the ex-factory number of the same screw
back-out turns to any required value provided in the chart.
For example, if the ex-factory number is "2", add "2" to the value chosen in the chart.
Examples of carburetor setting depending on symptom
Symptom
At full throttle
Stall at high speeds
*Hard breathing
Shearing noise
Whitish spark plug
Lean mixture
At full throttle
Speed pick-up stops
Slow speed pick-up
Slow response
Sooty spark plug
Rich mixture
Lean mixture
Rich mixture
1/4 ~ 3/4 throttle
*Hard breathing
Lack of speed
1/4 ~ 1/2 throttle
Slow speed pick-up
White smoke
Poor acceleration
Closed to 1/4 throttle
*Hard breathing
Speed down
General condition
Over 30 °C
15 ~ 25 °C
(86 °F)
(59 ~ 77 °F)
(Summer)
(Spring, Autumn)
#138
#135 ~ #138
NBKF-2
NBKF-2
#45
Zero
Setting
Increase main jet calibration no.
(Gradually)
Decrease main jet calibration no.
(Gradually)
*In case of racing slight enrich-
ment of mixture reduces engine
trouble.
Use jet needle with a smaller
diameter, or NBLF.
Lower jet needle clip position.
Use jet needle with a larger diam-
eter, or NBKG.
Raise jet needle clip position.
Use jet needle with a smaller
diameter, or NBLF.
Lower jet needle clip position.
Use jet needle with a larger diam-
eter, or NBKG.
Raise jet needle clip position.
Use jet needle with a smaller
diameter.
Turn out pilot air screw.
SETTING
Under 10 °C
(50 °F)
(Winter)
#142
NBKF-2
#45
#48
+1/4
–1/2
Discoloration of spark plug →
If tan color, it is in good condition.
If cannot be corrected:
Clogged float valve seat
Clogged fuel hose
Clogged fuel cock
Discoloration of spark plug →
If tan color, it is in good condition.
If cannot be corrected:
Clogged air filter
Fuel overflow from carburetor
The clip position is the jet needle
groove on which the clip is
installed. The positions are num-
bered from the top.
7 - 7
T U N
Sandy condition
Over 30 °C
15 ~ 25 °C
(86 °F)
(59 ~ 77 °F)
(Summer)
(Spring, Autumn)
#142
#142
NBKF-2
NBKF-2
#48
#48
–1/2
Zero ~ +1/2
Checking
Leaner
(Standard)
Richer