IDS uEye series User Manual page 198

Table of Contents

Advertisement

User Manual uEye Cameras V3.32
Internal supply voltage by sensor type
3.0 V
164xLE
155xLE
148xLE
I2C operation
Digital Input Wiring (Trigger)
Digital input specifications
Level low
Level high
Digital input wiring
198
3.3 V
122xLE
154xLE
146xLE
If the 3V3 and the 5V power supplies are used simultaneously, please observe that the
maximum power available from the USB bus is 2.5 W.
Multi master mode is not allowed on the I2C bus while the USB uEye LE camera is used.
From driver version 3.20, the I2C bus is operated with an effective clock frequency of
approx. 250 kHz. For earlier versions, the clock frequency is 100 kHz.
The digital input of the USB uEye LE is not potential-free and has no protective circuits.
Due to hardware limitations, the USB uEye LE can only be triggered on the falling edge.
Figure 183: Wiring of the trigger connector
Min.
Max.
0
0.8
2.0
5.25
© 2009 IDS Imaging Development Systems GmbH
V
V

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ueye seUeye reUeye leUeye he