User Manual uEye Cameras V3.32
For interpreting the trigger signal, either the positive or the negative edge can be used. The digital
input is galvanically isolated using an opto coupler to protect the camera and the PC against surges.
Only DC voltages may be applied to the digital input.
Digital input wiring
Digital Output Wiring (Flash)
Digital output specifications
USB board revision *
Output current (short-time)
Output current (permanent)
Output voltage
Breakdown voltage
Collector power dissipation
The digital input is galvanically isolated using an opto coupler to protect the camera and the PC
against surges. Only DC voltages may be applied to the digital input.
The output of the opto coupler can be used as an open collector or open emitter output. This means
that the output signal can be connected to ground or to the supply voltage. The output signal is
active if the collector-emitter switch is closed (software setting: Flash high active, see also the
Camera Properties: Input/Output section).
190
)
*
For information on how to determine the USB board revision, please refer to the USB
uEye SE Driver Compatibility chapter.
Figure 171: Wiring of the trigger connector
)
1.2
)
*
For information on how to determine the USB board revision, please refer to the USB
uEye SE Driver Compatibility chapter.
2.0 or higher
Max.
Max.
50
500
15
150
30
30
50
50
100
125
© 2009 IDS Imaging Development Systems GmbH
mA
mA
V
V
mW