Installing The Tape Library; Location Requirements - Fujitsu ETERNUS LT20 S2 Installing, Starting Up And Maintaining

Lto library
Hide thumbs Also See for ETERNUS LT20 S2:
Table of Contents

Advertisement

3

Installing the Tape Library

3.1

Location Requirements

Choose a location that meets the following criteria:
Criteria
Rack requirements
Room temperature
Power source
Weight without media 14 kg
Weight with media
(8 LTO cartridges)
Air quality
Humidity
Clearance
ETERNUS LT20 S2
Definition
Standard 19-inch rack with 1U of clearance
10-35º C (50-95º F)
AC power voltage: 100-127 VAC; 200-240 VAC
Line frequency: 50-60 Hz
Place the library near an AC outlet. The AC power
cord is the product's main AC disconnect device and
must be easily accessible at all times.
16.5 kg
The library should be placed in an area with minimal
sources of particulate contamination.
Avoid areas near frequently used doors and
walkways, stacks of supplies that collect dust, printers,
and smoke-filled rooms.
Excessive dust and debris can damage tapes and
tape drive.
20-80 percent RH non-condensing
Back: Minimum of 15.4 cm (6 inches)
Front: Minimum of 30.8 cm (12 inches) – for mailslot
Minimum of 60 cm to remove magazines (24 inches)
Sides: Minimum of 5.08 cm (2 inches)
17