Fujitsu ETERNUS LT20 S2 Installing, Starting Up And Maintaining page 98

Lto library
Hide thumbs Also See for ETERNUS LT20 S2:
Table of Contents

Advertisement

Tape Library Error Codes
Error Code Description
DA
In Wellness Test the barcode
reader has read different barcode
data for the same cartridge label
DB
External cooling fan error (fan
motion has stopped).
The sub code indicates which
drive sled fan is affected
F0
Drive Over temperature
Condition
Sub code 01: drive sled #1
F1
Drive Communication Error,
library controller has lost commu-
nication to drive
Sub code 01: drive sled #1
F2
Drive Sled not present
Sub code 00: drive sled #1
F3
Drive Hardware Error
F4
Drive Load Timeout
Drive has run in a timeout while
loading a tape
F5
Drive Unload Timeout
Drive has run in a timeout while
unloading a tape
98
Troubleshooting
User Action
Check barcode on scratch
cartridge and run 'library
Health Check' again. If the
error recurs, contact
technical support
Check if the indicated fan is
operational and not
obstructed. If the error
persists, contact technical
support
Check ambient temperature
conditions and check all fans,
after several occurrences
contact technical support
Retry operation; if not
successful contact technical
support
Retry operation; if not
successful contact technical
support
Cycle Power, after several
occurrences contact
technical support
Retry operation; if not
successful contact technical
support
Retry operation; if not
successful contact technical
support
ETERNUS LT20 S2

Advertisement

Table of Contents
loading