Wiring Biphase; Rs-232 - Bosch UPH-2D Series Instruction Manual

High speed pan/tilt system
Table of Contents

Advertisement

16
en | Installing the High Speed Pan/Tilt
Note: The power cable must be double insulated, i.e. each separate cable is individually insu-
lated, then contained in an outer insulated cover. The cable type must be chosen in accor-
dance with local and national wiring rules; recommended cable type H05RN-F 1mm
24 VAC and 230 VAC installations.
4.4

Wiring Biphase

To wire for Biphase, connect the C+ terminal wire to the B+ terminal and the C- terminal wire
to the B- terminal respectively.
4.5

RS-232

RS-232 is used for firmware upgrades only (see Figure 4.8).
Fig. 4.8 RS-232 Location
F01U.073.990 | Version 1.0 | 2007.07
CAUTION!
The device must be wired by skilled technical personnel. Never make any
!
changes or connections that are not described in this handbook. Failure to
follow the instructions indicated in this manual may result in system or safety
hazards, thus invalidating the guarantee.
CAUTION!
!
When wiring for external/outdoor environments, be sure to use appropriately
rated cables.
Instruction Manual
High Speed Pan/Tilt System
2
both for
Bosch Security Systems

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uph-3d seriesUph-zUph-z series

Table of Contents