When programming the telephone numbers for
Receiver 1 and Receiver 2, you must program a 0
as a 10. Programming a 0 in the telephone
number indicates the end of the dialing sequence.
Unless otherwise stated, program a 0 as a 0 in all
locations other than the telephone numbers for
Receiver 1 and Receiver 2, and the Call Back
Telephone Number.
6. If required, set the Test Report time. Program
any other required changes. Otherwise, factory
default settings are used. Refer to Section 15.21
Test Reporting Time on page 63 for more
information.
7. Enter command [9 6 0] and press [AWAY] to exit
from the Installer's Programming Mode.
Two beeps sound and the STAY and AWAY
indicators turn off. The system returns to the
disarmed state and is ready for use. Refer to
Section 2.4 Installer's Programming Commands on
page 10 for more information.
8. Use the Master Code to set the date and time.
Refer to Section 1.2.1 Setting the Date and Time for
more information.
1.2.1

Setting the Date and Time

1. Enter your Master Code and press [6][AWAY].
Three beeps sound and the STAY and AWAY
indicators flash.
2. Enter the day, month, year, hour, and minute in
DD, MM, YY, HH, MM format (where DD is the
day of the month, MM is the month of the year,
YY is the year, HH is the hour of the day, and
MM minute of the day) and press [AWAY].
Use 24:00 hour format when programming the
hour of the day.
Two beeps sound and the STAY and AWAY
indicators turn off. If a long beep sounds, there
was an error when you entered the date and time.
Example
To set the date and time for the 1st January 2006 at
10:30 PM, enter:
[2 5 8 0 6][AWAY][0 1 0 1 0 6 2 2 3 0][AWAY]
8
Introduction
1.2.2

Zone Defaults

The default zone settings for the control panel are
listed in Table 1. You can program Zones 1 to 4 to
any of the zone types. Refer to Table 2 for the zone
types you can select.
Table 1:
Zone
1
2
3
4
1.2.3

Zone Types

There are thirteen zone types to choose from when
programming zones for the ICP-CC404 Control
Panel. Refer to Section 14.3 Zone Programming on
page 54 for more information.
Table 2:
Type
0
1
2
3
4
5
6
7
Bosch Security Systems, Inc. | 12/08 | F01U089401-02
Zone Defaults
Zone Type
Zone
Zone Type
Delay-1
5
24-Hour Burglary
Handover
6
24-Hour Burglary
Handover
7
24-Hour Fire
Instant
8
24-Hour Tamper
Zone Types
Description
Type
Description
Instant
8
24-Hour Holdup
Handover
9
24-Hour Tamper
Delay-1
10
Reserved
Delay-2
11
Keyswitch
Reserved
12
24-Hour Burglary
Reserved
13
24-Hour Fire
24-Hour Medical
14
Chime only
24-Hour Panic
15