Arming The System In Stay Mode 1 - Bosch ICP-CC404 Installation Manual

Hide thumbs Also See for ICP-CC404:
Table of Contents

Advertisement

Two beeps sound and the AWAY indicator is
extinguished.
4.3

Arming the System in STAY Mode 1

Use STAY Mode 1 when you need to arm the
perimeter and unused areas of the premises to detect
a would-be intruder from entering the premises, while
at the same time moving freely within an
automatically isolated area.
Only the installer can program zones to automatically
isolate in STAY Mode 1. Refer to Section 14.3.6 Zone
Options 2 on page 58 for more information on setting
zones to automatically isolate in STAY Mode 1.
There are two methods to arm your system in STAY
Mode 1. You can always use the first method. You
can use the other method only if Option 2 is enabled
in Location 429 (refer to Section 18.6 Consumer
Options 2 on page 75).
Entry Guard Timer for STAY Mode
When arming the system in STAY Mode 1, an
optional entry timer called Entry Guard Timer for
STAY Mode can delay the siren, strobe, and bell
outputs if a zone that is not automatically isolated
activates an alarm. Entry Guard Timer for STAY
Mode is the delay time used for all zones, except 24-
Hour zones, when the system is armed in STAY
Mode 1 or STAY Mode 2.
If the Entry Guard Timer for STAY Mode is
programmed and a zone that was not automatically
isolated is activated, the codepad beeps twice per sec
until the Entry Guard Timer for STAY Mode expires
or the system is disarmed. If the alarm is not reset
before Entry Guard Timer for STAY Mode expires,
the system activates the strobe, bell, and siren
outputs.
Single button arming in STAY Mode 1
reports as User Code number 16.
To arm the system from STAY Mode 1 (method
one):
Enter your code and press [STAY].
Two beeps sound and the STAY indicator lights. Exit
Time starts.
The indicators for any zones that are programmed to
automatically isolate in STAY Mode 1 flash until Exit
Time expires. At the end of Exit Time, the zone
indicators turn off and the codepad sounds one short
beep.
To arm the system from STAY Mode 2 (method
two):
1. Press and hold [STAY].
2. When two beeps sound, release the button.
The STAY indicator is lit and Exit Time starts.
Bosch Security Systems, Inc. | 12/08 | F01U089401-02
ICP-CC404 | Installation Guide | 4.0
The indicators for any zones programmed to
automatically isolate in STAY Mode 1 flash until Exit
Time expires. At the end of Exit Time, the zone
indicators turn off and the codepad sounds one short
beep.
If a zone is not sealed at the end of Exit Time, the
zone is automatically isolated and is constantly lit on
the remote codepad. The zone becomes an active
part of the system again after it is resealed. For
example, if a window is open when Exit Time
expires, the window does not become an active part
of the system until it is closed. Opening the window
after Exit Time expires causes an alarm.
Forced Arming
Arming the system when a zone is not sealed is
known as forced arming. Refer to Section 14.3.6 Zone
Options 2 to enable forced arming for each zone.
If the STAY indicator does not light and a long beep
sounds when you attempt to arm the system in STAY
Mode 1, forced arming is not permitted. If this is the
case, you must seal all zones or manually isolate them
before you can arm the system.
4.4
Disarming the System from STAY
Mode 1
There are two methods to disarm the system from
STAY Mode 1. You can always use the first method.
You can use the other method only if Option 4 is
selected in Location 429 (refer to Section 18.6
Consumer Options 2 on page 75).
To disarm the system from STAY Mode 1 (method
one):
Enter your code and press [STAY].
Two beeps sound and the STAY indicator is
extinguished. The system is now disarmed.
You cannot use method two unless both
Options 2 and 4 are enabled in
Location 429.
To disarm the system from STAY Mode 1 (method
two):
A flashing zone indicator represents a previous alarm
in that zone. If this is the case, a valid User Code is
required to disarm the system using method one. To
enable method two, select Option 4 in Location 429
(refer to Section 18.6 Consumer Options 2 on page 75).
Press and hold [STAY].
When two beeps sound, release the button. The
STAY indicator is extinguished and the system is
disarmed.
Single button disarming from STAY
Mode 1 reports as User Code 16.
System Operations