The List Of The Bcd Function - AND AD-4430B Instruction Manual

Din rail weighing module
Hide thumbs Also See for AD-4430B:
Table of Contents

Advertisement

5.4.5.

The List Of The BCD Function

Function No.
Parameter
Function name
and range
bcd01
Output data
1 to 4
bcd02
Data transfer
1 to 3
mode
bcd03
Data transfer rate
5 to 1000
bcd04
Output logic of
1 to 2
data transfer
bcd05
Output logic of
1 to 2
negative sign
bcd06
Output logic of
1 to 2
status
bcd07
Output logic of
1 to 2
strobe
bcd08
Input selection
0 to 5
bcd09
Output selection
0 to 12
1 : Displayed weight
2 : Gross weight
3 : Net weight
4 : Data specified by BCD input
1 : Stream
2 : Automatic printing
3 : Manual printing
5 times/second
10 times/second
20 times/second
100 times/second
1000 times/second
1 : Positive logic
2 : Negative logic
1 : Positive logic
2 : Negative logic
1 : Positive logic
2 : Negative logic
1 : Positive logic
2 : Negative logic
0 : None
1 : Clear zero
2 : Clear tare
3 : Changing between gross weight and net weight
4 : Print command
5 :
key
0 : None
1 : Stabilization
2 : During tare
3 : Zero band
4 : Hold busy state
5 : HI output (Over upper limit)
6 : OK output (Within upper and lower limits)
7 : LO output (Under lower limit)
8 : During operating weighing (On)
9 : During operating weighing (1 Hz)
10 : During operating weighing (50 Hz)
11 : Alarm (Zero correction error and tare error )
12 : Busy
key
- 34 -
Description
Display linked to
Fnc03
Default
value
1
1
20
2
2
2
2
3
1
AD-4430B

Advertisement

Table of Contents
loading