4.6
Power Budget Calculations for Magnum 6K32 PM's with Fiber Media
Receiver Sensitivity and Transmitter Power are the parameters necessary to
compute the power budget. To calculate the power budget of different fiber media
installations using Magnum products, the following equations should be used:
OPB (Optical Power Budget) = P
(min) - P
T
where P
= Transmitter Output Power, and P
T
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
where the "Cable Loss" for 62.5/125 and 50/125
and the "Cable Loss" for 100/140 (Multi-mode) is 3.3 dB/km,
and the "Cable Loss" for 9/125 (Single-mode) is 0.5 dB/km
and the "Cable Loss" for 9/125 (Single-mode) is 0.4 dB/km (LXSC25)
and the "Cable Loss" for 9/125 (Single-mode) is 0.25 dB/km
(LXSC40)
and the "Cable Loss" for 9/125 (Single-mode) is 0.2 dB/km (LXSC70)
The following data has been collected from component manufacturer's (Agilent's and
Lucent') web sites and catalogs to provide guidance to network designers and installers.
Fiber
Speed,
Std.
Wave
Port
km
-
Mode
Std.
Module
fdx
length
(hdx)
nm
6KP4-
10Mb
Multi-
2
850 62.5/125
Mode
F10ST
FL
(2)
6KPM-
1300 62.5/125
100Mb
Multi-
2
FX
mode
(0.4)
MST, MSC
100Mb
Single-
18+
(0.4) 1300
6KPM-SSC
FX
mode
100Mb
Single-
40
6KPM-
(0.4) 1300
FX
mode
SSCL
100Mb
Multi-
2
1300 62.5/125
6KPM-
(0.4)
FX
mode
MTRJ
2
100Mb
Multi-
6KPM-
(0.4) 1300 62.5/125
FX
mode
MLC
15+
6KPM-SLC 100Mb
Single-
(0.4) 1310
Mode
FX
0.55
1000Mb Multi-
GBIC-
1300 62.5/125
mode
SXSC
10
1000Mb Single-
GBIC-
1300
mode
LXSC10
www GarrettCom com
.
.
Installation and User Guide (02/05)
(min)
R
= Receiver Sensitivity
R
µm
(M.m) is 2.8 dB/km,
Cable
X'mitr
R'cvr
Worst
Worst*
typical
Size
Output
Sens.
OPB,
distance
OPB,
µm
P
dB
P
dB
dB
Km, fdx
dB
T ,
R ,
-15.0
-31
14
5
17
100/140
-9.5
-31
19.5
5.9
23.5
50/125
-19.5
-31
19.5
3.4
13.5
-20
-31
9.0
14
3.0
50/125
-23.5
-31
5.5
2.0
12
9/125
-15
-31
14
17.5
28
9/125
-5
-34
29
58
32.5
-20
-31
9.0
3.0
15.8
50/125
-23.5
-31
5.5
12.2
2.0
-19
-31
12
4
16
9/125
-15
-28
11
22
-9.5
-17
5.5
2
12.5
50/125
9/125
-9.5
-20
8.5
17
10.5
38
typical*
distance
Km, fdx
6
7
4.8
5
4
35
65
5.5
4.0
5.7
-
-
4
21