Power Budget Calculations 6K32T & 6K32Trc Pm's - GarrettCom Magnum 6K32T Hardware User Manual

Garrettcom managed switch installation and user guide magnum 6k32t, 6k32trc
Hide thumbs Also See for Magnum 6K32T:
Table of Contents

Advertisement

Magnum 6K32T & 6K32TRC Managed Switch
The various SFPs transceivers supported by GarrettCom 6KQs D slot are-
Module Model#
Gb Modules, fixed ports--SFP (Small Form Factor)
6KP2-2GSFP
6KP2-1GSFP1CU
6KP1-1SFP
6KP1-1GCU
Gb SFP fiber optic transceivers
SFP-SX
SFP-LX10
SFP-LX25
SFP-ZX40
SFP-ZX70
3.2.7
Power Budget Calculations for Magnum 6K32T & 6K32TRC PM's with
Fiber Media
Receiver Sensitivity and Transmitter Power are the parameters necessary to
compute the power budget. To calculate the power budget of different fiber media
installations using Magnum products, the following equations should be used:
OPB (Optical Power Budget) = P
where P
= Transmitter Output Power, and P
T
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
where the "Cable Loss" for 62.5/125 and 50/125
www GarrettCom com
.
.
Gigabit
2 SFP
1SFP
1 CU
1SFP
1 CU
Gb SX, 850nm wavelength, 500 m distance
Gb LX, 1310nm wavelength, 10km dist
Gb LX, 1310nm wavelength, 25km
distance
Gb ZX, 1550nm wavelength, 40km
distance
Gb ZX, 1550nm wavelength, 70km
distance
(min) - P
(min)
T
R
32
Installation and User Guide 05/07)
= Receiver Sensitivity
R
µm
(M.m) is 2.8 dB/km,