4.4

Power Budget Calculations for 6KL Modules with Fiber Media

Receiver Sensitivity and Transmitter Power are the parameters necessary to
compute the power budget. To calculate the power budget of different fiber media
installations using Magnum products, the following equations should be used:
OPB (Optical Power Budget) = P
where P
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
where the "Cable Loss" for 62.5/125 and 50/125
and the "Cable Loss" for 100/140 (Multi-mode) is 3.3 dB/km,
and the "Cable Loss" for 9/125 (Single-mode) is 0.5 dB/km
and the "Cable Loss" for 9/125 (Single-mode) is 0.4 dB/km (LX25)
and the "Cable Loss" for 9/125 (Single-mode) is 0.25 dB/km (ZX40)
and the "Cable Loss" for 9/125 (Single-mode) is 0.2 dB/km (ZX70)
See
http://www.garrettcom.com/techsupport/power_budget.pdf
Power budget calculations
5.0

Magnum 6KL Managed Edge Switch Port Modules

This chapter describes each Port Module (PM), including appearance,
functionality, and status displays.
5.1

6KL Modules

An important feature of the Magnum 6KL is the use of Port Modules for
flexible mixed-media connectivity to RJ-45 copper and various fiber media. The first
four ports (1,2,3 & 4) of the Magnum 6KL Switches are fixed RJ-45 copper ports with
dual-speed 10/100Mbps auto-negotiating capability. Additionally the switch can accept
up to two Port Modules to provide the user with up to 6 additional ports (10 total)
providing a wide selection of Ethernet copper and fiber media connections with 10, 100
and 1000Mbps capability and up to 70km.
Note: The 6KL Port modules are not identical to the port modules used in other
6K products such as the 6K25e and 6K16V. For information about other
6K products, please see the applicable manual. For a list of 6KL Port
Modules, refer to Section 1.2
Each 6KL Port Module (PM) is individually described in the following sections.
www GarrettCom com
.
(min) - P
T
= Transmitter Output Power, and P
T
.
(min)
R
= Receiver Sensitivity
R
μ