Status Leds; Up-Link Cross-Over Switch On Rj-45 Port Modules; Auto-Cross (Mdix) - GarrettCom Magnum 6K32 Hardware Installation And User's Manual

Garrettcom managed switch hardware installation and user guide magnum 6k32
Table of Contents

Advertisement

Magnum 6K32 Managed Switch
Address Learning
All Magnum 6K32 units have address table capacities of 4K node addresses
suitable for use in larger networks. They are self-learning, so as nodes are added,
removed or moved from one segment to another, the 6K32 Switch automatically keeps
up with node locations.
An address-aging algorithm causes least-used addresses to fall out in favor of
frequently-used addresses. To reset the address buffer, cycle power down-and-up.
4.2

Status LEDs

For all Magnum 6K32 models :
PWR
: Power LED, ON when external power is applied to the unit.
LK
: Steady ON, Link status for 10 Mbps and 100Mbps operation.
ACT
: ON with port activity for 10 Mbps and 100Mbps operation.
F/H
: Full / Half duplex LED, ON when the port is running full
duplex, OFF for half duplex.
100/10
: Speed LED, ON when the speed is 100Mbps , OFF when the
speed is 10 Mbps
4.3
Up-link Cross-over Switch on RJ-45 port modules, for port#1 only
The modular slot provided on Magnum 6K32 managed switch can be filled
with 6KP8-RJ45 port module among all the multiple choices of port modules. The upper
part of the copper port module (6KP8-RJ45) has a manual Up-link switch, located on the
inside of the unit on the port module board next to the RJ45 port # 1 which it controls. It
enables the port's cable to be cascaded (X) to a 10/100Mb repeater or switching hub in
the network. The manual Up-link switch position is configured as (=) position as default
factory setting, where used for all-copper module or combo modules.
4.4
Auto-Cross (MDIX)Auto-negotiation, for 10/100Mbps RJ-45 ports
The 24 RJ-45 ports on Magnum 6K32 supports auto-cross (MDI or MDIX) in the
auto-negotiation mode according to the IEEE 802.3u standard. No crossover cables
are needed when connecting the 6K32's 10/100 copper ports to other unmanaged
switches, legacy hubs, managed switches, media-converters etc. Please note that
there can be conditions with managed switches where the switch manager fixes the
port settings via software, and the result of the auto-negotiation is changed in the
managed switch by the manager commands. In such cases, the 10/100 speed or the
F/H mode may be affected, but auto-cross in the 6K32 Switches will still work. The
auto-cross function can be disabled, if fixed the port at 10 or 100Mb through
software..