AOR AR-ONE Operating Manual page 68

Ultra wide band communications receiver
Hide thumbs Also See for AR-ONE:
Table of Contents

Advertisement

To read: AU <CR>
Response:
AUn
7-3-5 OPERATION MODE
MDn
(n: 0 - 6)
MD
n=0
FM (BW=16KHz,HPF=50Hz,LPF=3KHz,De-emphasis=750uS)
n=1
AM (BW=6KHz, HPF=50Hz, LPF=3KHz, De-emphasis=THRU)
n=2
CW (BW=0.5KHz, HPF=50Hz, LPF=3KHz, De-emphasis=THRU)
n=3
USB
n=4
LSB
n=5
WFM (BW=200KHz, HPF=50Hz, LPF=12KHz, De-emphasis=75uS)
n=6
NFM (BW=8.5KHz, HPF=50Hz, LPF=3KHz, De-emphasis=750uS)
To read: MD <CR>
Response:
MDn
7-3-6 BAND WIDTH
BW
BWn
(n: 0 – 6)
n=0
0.5KHz
n=1
3.0KHz
n=2
6.0KHz
n=3
8.5KHz
n=4
16KHz
n=5
30KHz
n=6
100KHz
n=7
200KHz
n=8
300KHz
n=9
5MHz
To read: BW <CR>
Response:
BWn
7-3-7 HPF (High Pass Filter)
HP
HPn
(n: 0 – 3 & F)
n=0
n=1
n=2
Auto mode will be disabled by this command
(BW=3KHz, HPF=50Hz, LPF=3KHz, De-emphasis=THRU)
(BW=3KHz, HPF=50Hz, LPF=3KHz, De-emphasis=THRU)
Auto mode will be disabled by this command
Auto mode will be disabled by this command
50Hz
200Hz
300Hz
67