AOR AR-ONE Operating Manual page 63

Ultra wide band communications receiver
Hide thumbs Also See for AR-ONE:
Table of Contents

Advertisement

keeping
an eye on a distress frequency while scanning or searching another frequency band.
Note: Depending upon the frequency and mode stored as priority, an audible click may be
heard when the priority function is in operation. This is quite normal and is caused by the
internal switching of circuitry necessary to accomplish the frequency change (as two
frequencies cannot simultaneously be monitored).
6-15-1 Engaging Priority channel
Once engaged, the frequency is checked for activity periodically by the preset period that is
set by the configuration menu.
To engage the priority function, push the FUNC key and then push the 7 key.
Push the down arrow key to move the cursor to "PRIO-CH" selection point.
This menu is to configure the priority channel.
Use the main tuning dial or the right arrow key or the left arrow key to select the desired
priority channel.
Push the downward key to select the time interval.
Use the main tuning dial or the right arrow key or the left arrow key to select the desired
time
interval for the priority channel.
Push the ENT key to accept data and return to a standard display.
Alternatively, push the ESC key to abort entry.
62