Using your Programmable Power Supply
Local sensing (outputs in series):
Connect the load wires to the +V terminal of output channel 1 and the -V terminal
of output channel 2, and interconnect the -V terminal of output channel 1 and the
+V terminal of output channel 2. Connecting the +S of output channel 2 to the -S
of output channel 1, while removing the local sense jumper between +S and +V
of output channel 2, will compensate for the voltage drop across the wires from
output channel 2 to output channel 1. The following diagram shows the wiring
scheme.
+S
+V
OUTPUT 1
V
S
+S
+V
OUTPUT 2
V
S
Figure 5.6.3 Local Sensing with Two Outputs in Series
+
LOAD
ST5874