Store/Recall Function - Fluke PM2811 User Manual

Programmable power supplies
Table of Contents

Advertisement

Using your Programmable Power Supply
The overvoltage protection level OVP
subsystem command:
The overvoltage protection level OVP
subsystem query:
Example:
Send
:VOLT:PROT 7
Send
:MEAS:PROT?
Read
meas_over_voltage
Print meas_over_voltage
The overcurrent protection can be enabled/disabled by the SOURCE subsystem command:
[:SOURce]:CURRent:PROTection:STATe
Example:
Send
:CURR:PROT:STAT ON
Send
:CURR:PROT:STAT OFF Disable overcurrent protection.
5.5.4

Store/recall function

Your programmable power supply has a recall memory (battery backed up) to be
used for storing and recalling voltage and current settings of all output channels.
The battery back up feature ensures that the stored values will be kept in memory
during power-off. The recall memory consists of 999 addresses, numbered from
1 to 999. A recall memory address contains space for the voltage and current
setting of all available output channels.
address 1
address 2
address 998
address 999
set
[:SOURce]:VOLTage:PROTection[:LEVel]
set
[:SOURce]:VOLTage:PROTection[:LEVel]?
output channel 3
output channel 2
output channel 1
voltage 1
current 1
voltage 2
current 2
voltage 998
current 998
voltage 999
current 999
can be programmed by the SOURCE
can be requested by the SOURCE
Set 7V protection level.
Send readback query.
Read overvoltage protection level.
Display overvoltage protection level.
Enable overcurrent protection.
5 - 19