To configure the LACP timeout period on a CEE interface, perform the following steps from
privileged EXEC mode.
1. Enter the configure terminal command to access global configuration mode.
2. Enter the interface command to specify the CEE interface type and slot/port number.
3. Enter the no shutdown command to enable the CEE interface.
4. Specify the LACP timeout period for the CEE interface.

Clearing LACP counter statistics on a LAG

To clear LACP counter statistics, perform the following task from privileged EXEC mode.
Enter the clear command to clear the LACP counter statistics for the specified LAG group number.

Clearing LACP counter statistics on all LAG groups

To clear LACP counter statistics, perform the following task from privileged EXEC mode.
Enter the clear command to clear the LACP counter statistics for all LAG groups.

Displaying LACP information

Use the show command to display LACP statistics and configuration information. See the
Converged Enhanced Ethernet Command Reference for information.

LACP troubleshooting tips

To troubleshoot problems with your LACP configuration, use the following troubleshooting tips.
If a standard IEEE 802.3ad-based dynamic trunk is configured on a link and the link is not able to
join the LAG:
Converged Enhanced Ethernet Administrator's Guide
53-1002163-02
DRAFT: BROCADE CONFIDENTIAL
switch(config)#interface tengigabitethernet 0/1
switch(conf-if-te-0/1)#lacp timeout short
switch#clear lacp 42 counters
switch#clear lacp counters
Make sure that both ends of the link are configured as standard for the trunk type.
Make sure that both ends of the link are not configured for passive mode. They must be
configured as either active/active, active/passive, or passive/active.
Make sure that the port-channel interface is in the administrative "up" state by ensuring that
the no shutdown command was entered on the interface on both ends of the link.
Make sure that the links that are part of the LAG are connected to the same neighboring
switch.
Make sure that the system ID of the switches connected by the link is unique. This can be
verified by entering the show lacp sys-id command on both switches.
LACP troubleshooting tips