6.3. CF-Functions

Item
CF00
Zero tracking width,
motion detection
condition
CF01
Push zero range
CF02
Power on zero range
Turning the display on,
the range to zero display.
CF03
Zero tracking
CF04
TARE, ZERO in motion /
TARE at negative gross
value
CF05
Output on overload and
unstable state.
CF06
Header 2
CF07
Number of unit digits
CF08
Accumulation function
CAP : maximum capacity
Power on ZERO (CF02)
CF02=0
After power on, the weight display starts immediately.
CF02=1,2,3
When the zero range is exceeded at power on, ------ is displayed.
Press the ESC key to start the weight display.
AD-4406 Weighing Indicator
Parameter
* 0
No limitation
1
Use limitation at F01, F02, F03, F27 and F28
* 0
2% of CAP, Tare limit is 100 % CAP
1
10% of CAP, Tare limit is 100 % CAP
2
3% of CAP, Tare limit is 50 % CAP
3
4% of CAP, Tare limit is 50 % CAP
0
Not to zero when turning the display on.
*1
10% of CAP
2
3% of CAP
3
4% of CAP
0
Gross when displaying gross
1
Gross
* 2
Gross or Net when displaying net
TARE, ZERO in motion / TARE at negative gross
* 0
Not to execute
1
Execute
2
Not to execute
3
Execute
Not to output data at unstable value or overload
* 0
Effective in key mode
1
To output data always
GROSS / NET / TARE
* 0
GS
/ NT / TR
1
GS
/ NT / TR
2
G_
/ N_ / T_ (_:Space 20h)
* 0
Two digits
1
Three digits
* 0
Not used (Ineffective)
1
Used
Page 29
Description
/
Not to execute
/
Not to execute
/
Execute
/
Execute
(Effective)
*:
Initial settings
6.3. CF-Functions