Reinstalling Pcu, Face Plate, Toner Hopper - Toshiba e-STUDIO4500c Service Manual

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO4500c:
Table of Contents

Advertisement

August, 2006

Reinstalling PCU, Face plate, Toner Hopper

To reinstall a PCU:
1. Hold the PCU [A] in front of the slot where you removed it
2. Engage the rails [B] with the slots in the sides of the PCU.
3. Slowly push the PCU into the slot. Make sure the
release tab [C] above the PCU is locked.
NOTE: If the PCU does not go in smoothly,
make sure the rails [B] and grooves are
engaged correctly.
Important!
If you have replaced a developer
cartridge in a PCU, be sure to remove
the film seals [D] of every replaced
developer cartridge after you reinstall it
in the machine.
To release the developer into the PCU,
pull out the film seal [D].
NOTE: Put your other hand on the
PCU [E] to keep it stable it while you
pull on the film seal.
COMMON REMOVAL PROCEDURES
[A]
[D]
[E]
3-15
[B]
B132I114.WMF
[B]
B132I905.WMF
B132I101.WMF