SPECIAL PROCEDURES
When viewed through the lupe, the grid lines on the left and right side should
be perfectly aligned (Good) and not misaligned (No-Good).
4. If the lines are misaligned (No-Good), use the lupe to measure distance
between the black vertical lines and each of the colored vertical lines (C, M, Y).
Measure this on the left and right folds:
If there is a gap between the black lines and a colored line, measure it and
correct it with SPs as shown in the tables below.
Left
Right
Remarks
Gap on the left
is different from
the gap on the
right
2112 001 (M) Left Fold
2112 002 (M) Right Fold
2112 003 (C) Left Fold
2112 004 (C) Right Fold
2112 005 (Y) Left Fold
2112 006 (Y) Right Fold
Unit of adjustment: 50 m
Gaps are the
same or
different.
B132R942.WMF
SP
4-14
April, 2007
Action
To move a color toward
the left edge, decrease
the SP value.
To move a color toward
the right edge, increase
the SP value.