PCU (PHOTOCONDUCTOR UNITS)
[B]

Removing the Cleaning Blade

Remove:
PCU ( 3.2.7)
Charge roller unit ( 3.5.3)
Drum ( 3.5.4)
Open the upper cover of the cleaning unit 90 degrees to the right.
[A]: Bracket
[B]: Cleaning blade (
Important
After you replace the cleaning blade, always coat the drum with Lubricant
Powder B1329700. (For more, see the next page.) This must be done even if the
drum is not replaced.
x2)
3-52
August, 2006
[A]
B132R206.WMF