SECTION 3. INSTRUCTION SET BASICS
Section 3.7.1 does not apply to the TD operating system which does not use Output Flag 0.
Table 3.8-1 Valid Flag Commands are 11 – 19 to set high and 21- 29 to set low. Because the TD
operating system does not use Flag 0, Commands 10 and 20 are not valid with the TD operating system.
The following table replaces Table 3.10-1 for the TD operating system.
TABLE 3.10-1. Error Codes
Code
Type
Description
03
Editor
Program table full
04
Compile
Intermediate Storage full
05
Compile
Storage Area #2 not
allocated
08
Run Time
CR10X reset by
watchdog timer
09
Run Time
Insufficient Input Storage
10
Run Time
Low Battery Voltage
11
Editor
Attempt to allocate more
Input or Intermediate
Storage than is available
20
Compile
SUBROUTINE encountered
before END of previous
subroutine
21
Compile
END without IF, LOOP or
SUBROUTINE
22
Compile
Missing END
23
Compile
Nonexistent
SUBROUTINE
24
Compile
ELSE in SUBROUTINE
without IF
25
Compile
ELSE without IF
26
Compile
EXIT LOOP without
LOOP
27
Compile
IF CASE without BEGIN
CASE
28
Compile
At compile time, no
output specified after P84
or unable to automatically
allocate at least one
record per P84
29
Compile
Output table requests
more memory than
available
30
Compile
IF and/or LOOP nested
too deep
31
Run Time
SUBROUTINES nested
too deep
32
Compile
Instruction 3 and interrupt
subroutine use same port
33
Compile
Cannot use Control Port
6 as counter or interrupt
subroutine with
Instruction 15 or SDM or
SDI-12 input/output
40
Editor
Instruction does not exist
41
Editor
Incorrect execution
interval
43
Compile
Time in Instruction 84 or
92 is not a multiple of
execution interval (note:
time is in seconds)
44
Compile
Loop (P87) cannot
contain Data Table (P84)
60
Compile
Insufficient Input Storage
61
Compile
Burst Measurement Scan
Rate too short
62
Compile
N<2 in FFT
68
Compile
Instruction 118 without
enough Instructions 68 or 63
80
Compile
Illegal Interval in P193
81
Compile
Illegal Node ID in P193
82
Compile
Illegal Reps in P193
92
Compile
Instruction 92, intervals in
seconds: Time into Interval
> 59 or Interval > 60
AD-3-1

Advertisement