Ov5.3 Setting The Datalogger Time - Campbell CR510 Operator's Manual

Datalogger
Hide thumbs Also See for CR510:
Table of Contents

Advertisement

Instruction #
(Loc.:Entry)
07: P73
08: P74
The program to make the measurements and to send the desired data to Final Storage has
been entered. At this point, Instruction 96 is entered to enable data transfer from Final Storage
to Storage Module.
09:P96

OV5.3 SETTING THE DATALOGGER TIME

The next example shows how to set the datalogger date and time using the CR10KD. Here the
example reverts back to the key-by-key format.
Key
5
A
1
9
9
A
1
9
7
A
1
3
2
A
0
Parameter
(Par.#:Entry)
01:1
02:10
03:2
01:1
02:10
03:1
1:71
Display
Explanation
00:21:32
Enter 5 Mode. Clock running but perhaps not set correctly.
05:0000
Advance to location for year.
8
05:1998
Key in year (1998).
05:0000
Enter and advance to location for Julian day.
05:197
Key in Julian day.
05:0021
Enter and advance to location for hours and minutes (24 hr. time).
4
05:1324
Key in hrs.:min. (1:24 PM in this example).
:13:24:01
Clock set and running.
LOG 1
Exit 5, compile Table 1, commence logging data.
Description
Maximize instruction
One repetition
Output time of daily maximum in hours and minutes
Data source is Input Storage Location 1.
Minimize instruction
One repetition
Output the time of the daily minimum in hours
and minutes
Data source is Input Storage Location 1.
Activate Serial Data Output.
Output Final Storage data to Storage Module.
CR510 OVERVIEW