TD ADDENDUM  SECTION 1. FUNCTIONAL MODES
to which memory is cleared on powerup, to set
the PakBus ID, and to set communication to full
or half duplex.
CSI datalogger support software makes use of the
∗D Mode to upload and download programs from a
computer. Appendix C gives some additional
information on Commands 1 and 2 that are used
for these operations.
When "∗D" is keyed in, the CR10X will display
"13:00". A command (Table 1.8-1) is entered
by keying the command number and "A".
TABLE 1.8-1. ∗D Mode Commands
Command
Description
1
Send (Print) ASCII Program
Load ASCII Program, ∗0 Compile
2
Load ASCII Program, ∗6 Compile
2--
3
# Rings Before Answering Phone
7
Erase Current Program
10
Set Powerup Options
12
Set Initial Baud
15
PakBus Address/Routing Table
16
Memory for General Purpose File
17
PakBus Routing Table
18
PakBus Beacon Interval
19
PakBus Neighbor List
If the CR10X program has not been compiled
when the command to save a program is entered,
it will be compiled before the program is saved.
When a program is loaded, it is immediately
compiled and run. When a command is complete,
"13:0000" is displayed; ∗D must be entered again
before another command can be given.
TABLE 1.8-2. Program Load Error Codes
E 94
Program Storage Area full
E 95
Program does not exist in flash
E 96
Storage Module not connected or
wrong address
E 97
Data not encountered within 30 sec.
E 98
Uncorrectable errors detected
E 99
Wrong type of file or Editor Error
1.8.1 ERASING CURRENT PROGRAM
The 7 command may be used to delete the
current program as show in Table 1.8-3.
AD-1-4
TABLE 1.8-3 Deleting Current Datalogger
Key entry
Display
∗D
13:00
7A
07:00
You may now enter:
0A
Erase active program (i.e., load a
blank program; memory allocation
and Final Storage are reset).
1.8.2 PROGRAM TRANSFER WITH STORAGE
MODULE
Not supported in Table Data Operating
Systems.
1.8.3 FULL/HALF DUPLEX
Not supported in Table Data Operating
Systems.
1.8.4 SET DATALOGGER ID
Command 8 not supported in Table Data
Operating Systems.

1.8.5 SETTING POWERUP OPTIONS

Setting options for the Program on Powerup
allows the user to specify what information to
retain from when the datalogger was last on.
This allows Flag/Port status, the User Timer,
and the Input/Intermediate Storage to be
cleared or not cleared.
Table 1.8-8. Setting Powerup Options
Key entry
Display
∗D
13:00
10A
10:0X
Where X is the powerup option currently
selected. You may now change the option:
0A
Clears input locations, ports, flags, user
timer, and intermediate storage locations.
1A
Clears intermediate storage only (leaves
Input Storage, Flags/Ports, and User Timer
as is).
2A
Doesn't clear anything.
Program