Memory Options - HP ProLiant ML100 Series User Manual

Proliant ml100 series
Hide thumbs Also See for ProLiant ML100 Series:
Table of Contents

Advertisement

NOTE:
Slide the media device part of the way into the bay.
7.
Connect the SATA power cable to the media drive.
8.
Connect the device cable to the device and the system board or to an expansion board, as directed
9.
by the option documentation.
Slide the media drive fully into the bay until it is seate
10.
Install the fan holder.
11.
Install the access panel.
12.
Do one of the following:
13.
Close or install the tower bezel, as needed.
o
Slide the server back into the rack.
o
Power up the server (on page 6).
14.
Mem
ory options
IMPORTANT:
these two types c
The memo
ry subsystem in this server can support RDIMMs or UDIMMs. Both types are referred to as
DIMM w
s
hen the information applies to both types. When specified as RDIMM or UDIMM, the
information applies to that type only. All memory
The server supports the following DIMM speeds:
Single- and dual-rank PC3-10600 (DDR-1333) DIMMs operating at 1333 and 1066 MHz
Quad-rank PC3-8500 (DDR-1067) DIMMs operating at 1066 MHz
HP recommends that you remove all bezel blanks to facilitate drive installation.
This server does not support mixing RDIMMs and UDIMMs. Attempting to mix
auses the server to halt during BIOS initialization.
d securely.
installed in the server must be the same type.
Hardware options installation 18

Advertisement