HP 37717C Calibration Manual page 86

Communications performance analyzer
Hide thumbs Also See for 37717C:
Table of Contents

Advertisement

General Information
Specifications
GRAPHICS and LOGGING
Graphic display or printout:
Barchart (results versus 60 time
periods) for current or stored
measurement period.
Bar resolution: 1 second, 1, 15, 60
minutes.
Unframed PDH bar graphs: Bit error
count, code error count, frame error
count, CRC error count, REBE error
count and PDH alarms.
Structured PDH bar graphs: Bit error
count, code error count, 140M frame
error count, 34M frame error count, 8M
frame error count, 2M frame error
count, CRC error count, REBE error
count, M2120 Reports and SPDH
alarms.
If Option A1T or A3R (SDH) is fitted
bar graphs of DS3 frame count, DS1
frame count, P-bit count and C-bit
count are available.
SDH bar graphs: RS B1 BIP error
count, MS B2 BIP error count, MS
FEBE error count, Path B3 BIP error
count, Path FEBE error count, Path IEC
error count, TU BIP error count, TU
FEBE error count and SDH alarms.
Jitter bar graphs: Jitter hit count and
Jitter alarms.
Wander bar graphs: Frame slip count
and Bit slip count.
ATM bar graphs: EM BIP count,
FEBE error count, CRC4 error count,
REBE error count, Corrected HEC
count, Non corrected HEC count, Non
conforming cell count, Bit error count,
Cell loss count, Misinserted cell count,
Errored cell count, BEDC count and
ATM alarms.
Printer
Internal: 24-column thermal printer.
External: 80-column HP 550C Deskjet
printer (HP-IB).
HP 550C Deskjet printer or 40 column
or 80 column printer (RS-232-C).
HP 550C Deskjet printer or 40 column
or 80 column printer (Centronix)
Printing: Results, time, date and
instrument control settings.
Print triggers: Power up, manual, start
of test period, turning printer on during
test period, any alarm or error second,
start of new day.
Print period: 10 minutes, 1 hour, 24
hours, user-defined (10 to 99 minutes or
1 to 99 hours).
Disk Drive:
Configurations: Save/recall of
instrument configurations to/from
floppy disk drive (in addition to the 5
internal stored settings).
Graphics: Save/recall of stored
measurement graphics to/from floppy
disk drive. Extends internal event based
storage from 20,000 events to 320,000
events.
Logging: Direction of logging output
to floppy disk drive.
PC results format: Save SMG stored
results in a CSV (comma separated
variable) PC compatible format for
importing to PC spreadsheets etc.
Disk management: Provides the
following disk drive features:
1-65