HP 37717C Calibration Manual page 368

Communications performance analyzer
Hide thumbs Also See for 37717C:
Table of Contents

Advertisement

Performance Tests
Performance Test Record
Table 11
Page
Test Description
No.
ETSI/ANSI Internal Transmitter Clock Rates (Option UKZ)
DS3 Frequency Accuracy
3-176
Step 3
Frequency
Step 5
Frequency
3-177
Step 7
Frequency
E1 (2.048Mb/s) Frequency
Accuracy
Step 2
Frequency
Step 4
Frequency
Step 6
Frequency
E3 (34.368Mb/s) Frequency
Accuracy
Step 2
Frequency
Step 4
Frequency
Step 6
Frequency
DS1 Frequency Accuracy
3-178
Step 2
Frequency
Step 4
Frequency
Step 6
Frequency
Transmitter Output Level and Waveshape (Option UKZ)
34.368 Mb/s Positive Pulse
3-181
Step 8
Pulse Mask
Step 9
peak pulse amplitude
34.368 Mb/s Negative Pulse
3-182
Step 7
Pulse Mask
Step 8
peak pulse amplitude
2.048 Mb/s Positive Pulse
Performance Test Record
Result
44735798.6 Hz
44736693.4 Hz
44734904.0 Hz
2047985.6 Hz
2048088 Hz
2047883.2 Hz
34367759.4 Hz
34368446.8 Hz
34367072.0 Hz
1543993 Hz
1544042.4 Hz
1543943.6 Hz
900 mV
900 mV
Min
Actual
Pass/Fail
Pass/Fail
Max
44736201.4 Hz
44737096.0 Hz
44735306.6 Hz
2048014.4Hz
2048116.8 Hz.
2047912.0 Hz
34368240.6 Hz
34368928 Hz
34367553.2 Hz
1544007 Hz
1544056.4 Hz
1543957.6 Hz
1.100 Volts
1.100 Volts