ORIG BPM (Original BPM)
This indicates the tempo of the sample. For a sample that was captured by
the microSAMPLER, the tempo specified at the time of sampling (☞p.18 "2.
Setting the tempo") is stored as the original tempo.
ORIG.RATE (Original Rate)
This indicates the sampling rate of the sample. For a sample that was cap-
tured by the microSAMPLER, the sampling rate specified at the time of sam-
pling (☞p.23 "RATE") is stored as the original sampling rate.

3. DELETE SAMPLE

DEL SMPL .............................................................. [DEST ALL, DEST 01...36]
This lets you delete unwanted samples from the selected bank.
1.
Press the [EDIT] button to make it blink.
If the [EDIT] button is not blinking, press it again until it blinks.
2.
Use the [PARAMETER/FX CONTROL 1] knob to select the "SAMPLE"
page.
3.
Press the [EDIT] button to make it light-up.
4.
Use the [PARAMETER/FX CONTROL 1] knob to select the "DEL
SMPL" page.
5.
Use the [VALUE/FX CONTROL 2] knob to select the sample that you
want to delete.
You can choose "DEST ALL" or "DEST 1–36."
If you select "ALL," all samples of the selected bank will be deleted.
6.
Press the [ENTER/SHIFT] button.
7.
When the display asks "SURE?," press the [ENTER/SHIFT] button once
again to confirm. If you decide to cancel, press the [EXIT] button to
return to step 5.
When the sample data has been deleted, the screen will indicate "COM-
PLETE."

4. SWAP SAMPLE

SWAP.SMPL ..............................................................................[DEST 01...36]
This lets you exchange the current sample (☞p.18) of the selected bank with
the sample number that you specify.
1.
Press the [EDIT] button to make it blink.
If the [EDIT] button is not blinking, press it again until it blinks.
2.
Use the [PARAMETER/FX CONTROL 1] knob to select the "SAMPLE"
page.
3.
Press the [EDIT] button to make it light-up.
4.
Use the [PARAMETER/FX CONTROL 1] knob to select the
"SWAP.SMPL" page.
5.
Use the [VALUE/FX CONTROL 2] knob to select the number of the
sample that you want to exchange with the current sample (☞p.18).
6.
Press the [ENTER/SHIFT] button.
7.
When the display asks "SURE?," press the [ENTER/SHIFT] button once
again to confirm. If you decide to cancel, press the [EXIT] button to
return to step 5.
When the sample data has been exchanged, the screen will indicate
"COMPLETE."