Table A-2 Missing Components (continued)
Data 2
0x1E
0x1E

Chassis Control Event Codes

For BMC rev 1.41+, an SEL event will be logged for each ChassisControl event, whether it's
generated by an IPMI request, or a sensor event.
Later revisions of MP firmware recognize the triplet (12:70:A3) as ChassisControl.
The EventData fields are:
Data1: 0xA3 (indicating OEM data in Data2 and Data3, and OEM offset 3)
Data2:
[7] 0 = Request generated by a Sensor Event
1 = IPMI request
[6-4] Reserved
[3-0] ChassisControl command
Data3: Sensor Number or IPMI Request Origin
Table A-3 Chassis Control Commands
Command
0x00
0x01
0x03
0x04
0x0D
0x0E
Table A-4 Sensor Numbers
Sensor Number
0x04
0x0E
0x11-13
0x40
0xCD-D3, 0xD5-D6
0xD8
0xD9-DA
0xFA
Table A-5 IPMI Origins
Number
0x00
0x03
Data 3
Missing Component
0x01
Cooling Unit 2
0x03
Cooling Unit 3
Description
Hard Power Down
Power Up
Hard Reset
NMI/TOC/INIT
Soft Shutdown and Restart
Soft Shutdown
Description
Power Button
Wake On LAN
Cooling Units
Power Supply
Voltage Sensors
Ambient Temperature
CPU Temperatures
ACPI
Source
block transfer (BT)
command line interface (CLI)
EFI Error and Warning Messages