Sel And Fpl Log Entries; Accessing The Logs With Bmc Cli Commands - HP Integrity rx1620 Operation Manual

Rsvla-0406
Hide thumbs Also See for Integrity rx1620:
Table of Contents

Advertisement

Table A-1 EFI Error and Warning Messages (continued)
Error
Error/Warning Message
Number
49
EFI NVM cleared
50
EFI NVM failed
51
CPU deconfigured by SAL_B
52
A ROM revision is inconsistent with FIT or
REVBLOCK
53
Error building SMBIOS
54
Failure constructing the EFI Memory Data Table
(MDT)
55
Universal Unique IDentifier (UUID) error
56
Error reading CPU SMBIOS information ROM
57
Error accessing Field Replaceable Unit (FRU)
information
58
Checksum error accessing FRU information
59
FRU information version error

SEL and FPL Log Entries

This section is a quick reference for the intelligent platform management interface (IPMI) events
recorded in the SEL and FPL files. These logs are available via the management processor (MP)
card interface or the BMC command line interface (CLI).
All entries from the SEL are forwarded to the FPL. The FPL is a circular log so the newest
entries replace the oldest. The FPL contains forward progress messages from the BMC,
System firmware, EFI, and the OS.
The SEL will not accept new entries once it is full and contains only those events considered
of major importance to system operation.
Both contain type 02 and E0 messages.
A triplet is formed from the SensorType, EventType, and the lower nibble of the Data1 fields
of Type 02 events. MP firmware displays the triplet in the Keyword field.
NOTE:
Systems with firmware version 2.0 or higher also have a clearlogs command that
will clear out the log files should they become full.

Accessing the logs with BMC CLI commands

The cli>sl -fcommand displays the forward progress log. For example:
Rec#
Sev Generator/Sensor Description
-------- - ---------------- ------------ ----------- --------------------------
00000000 - BMC
Event ID
Chass cntrl
00-12:70:A3 81:03
Solution
Information only, no action required
Reboot the server. If the error message is
repeated, contact the HP Support center for
assistance.
Check processor installation. (Verify
installation.) Replace processor that was
deconfigured.
One or more firmware components (Firmware,
BMC, MP) is out of date
Contact the HP Support center for assistance.
Contact the HP Support center for assistance.
Update with sysset command.
Reboot the server. If the error message is
repeated, replace the failing processor.
Replace the FRU which was reported. If the error
message is repeated, contact the HP Support
center for assistance.
Replace the FRU which was reported. If the error
message is repeated, contact the HP Support
center for assistance.
Replace the FRU which was reported. If the error
message is repeated, contact the HP Support
center for assistance.
Data, Timestamp
2003-10-31 22:41:29
EFI Error and Warning Messages
103

Advertisement

Table of Contents
loading

Table of Contents