6. Monitoring and Configuring the Printer
Configuring a sending protocol for SNMP v3 TRAP
msh> snmp v3trap {1-5} active {ipv4|ipv6|ipx} {on|off}
Configuring a user account for SNMP v3 TRAP
msh> snmp v3trap {1-5} account "account_name"
• Enter an account name using up to 32 alphanumeric characters.
Deleting an SNMP v3 TRAP user account
msh> snmp v3trap {1-5} clear account
Configuring an SNMP v3 encryption algorithm
msh> snmp v3auth {md5|sha1}
Configuring SNMP v3 encryption
msh> snmp v3priv {auto|on}
• Set "auto" for automatic encryption configuration
• Set "on" for mandatory encryption configuration.
6

sntp

The printer clock can be synchronized with a NTP server clock using Simple Network Time Protocol (SNTP).
Use the "sntp" command to change SNTP settings.
View settings
msh> sntp
NTP server address configuration
You can specify the IP address of the NTP server.
msh> sntp server "IP_address"
Interval configuration
msh> sntp interval "polling_time"
• You can specify the interval at which the printer synchronizes with the operator-specified NTP
server. The default is 60 minutes.
• The interval can be entered from 0, or between 16 and 10,080 minutes.
• If you set 0, the printer synchronizes with the NTP server only when you turn the printer on. After
that, the printer does not synchronize with the NTP server.
Time-zone configuration
msh> sntp timezone "+/-hour_time"
• You can specify the time difference between the printer clock and NTP server clock. The values
are between -12:00 and +13:00.