4. Remove the ground wire fixing screw.
5. Remove the clamp screw.
6. Remove the four + screws.
Figure 6-16. Removal of the Shift Unit
7. Remove three +screws and remove the Shift Pulley.
8. Slide the Conveyance Slide Shaft and take out the Shift Unit.
Figure 6-17. Removal of the Shift Unit
[Assembling Procedures]
1. Reinstall the Shift Unit by reversing the procedure above.
CAUTION:
When reinstalling the Shift Unit, be sure to align the Conveyance Slide Shaft with the
hole in the Shift Pulley.