Available languages

Air conditioner power supply cord trips (Reset button
pops out)
Disturbances
in your electrical current can trip (Reset
button will pop out) the power supply cord. Press and
release RESET (listen for click; Reset button will latch and on
some devices, a green light will turn on) to resume operation.
Electrical
overloading,
overheating,
cord pinching
or
aging can trip (Reset button will pop out) the power
supply cord. After correcting the problem, press and release
RESET (listen for click; Reset button will latch and on some
devices, a green light will turn on) to resume operation.
NOTE: A damaged power supply cord must be replaced with a
new power supply cord obtained from the product manufacturer
and must not be repaired.
Air conditioner
seems to run too much
The current air conditioner replaced an older model. The
use of more efficient components
may cause the air
conditioner
to run longer than an older model, but the total
energy consumption
will be less. Newer air conditioners
do
not emit the "blast" of cold air you may be accustomed
to
from older air conditioners,
but this is not an indication of
lesser cooling capacity or efficiency. Refer to the efficiency
rating (EER) and capacity rating (in Btu/h) marked on the air
conditioner.
The air conditioner is in a heavily occupied room, or heat-
producing appliances are in use in the room. Use exhaust
vent fans while cooking or bathing and try not to use heat-
producing appliances during the hottest part of the day. A
higher capacity air conditioner
may be required, depending
on the size of the room being cooled.
Air conditioner
cycles on and off too much or does not
cool room in cooling mode
The air conditioner is not properly sized for your room.
Check the cooling capabilities of your window air conditioner.
Window air conditioners
are not designed to cool multiple
rooms.
The filter is dirty or obstructed
by debris. Clean the filter.
The inside evaporator
and outside condenser coils are
dirty or obstructed
by debris. See "Annual Maintenance."
There is excessive
heat or moisture
(open container
cooking,
showers,
etc.) in the room. Use a fan to exhaust
heat or moisture from the room. Try not to use heat-
producing appliances during the hottest part of the day.
The louvers are blocked.
Install the air conditioner in a
location where the louvers are free from curtains, blinds,
furniture, etc.
The outside temperature
is below 65°F (18°C). Do not try to
operate your air conditioner
in the cooling mode when the
outside temperature
is below 65°F (18°C).
The temperature
of the room you are trying to cool is
extremely
hot. Allow extra time for the air conditioner to cool
off a very hot room.
Windows
or doors to the outside are open. Close all
windows and doors.
The temperature
setting
is not set to a cool enough
setting. Adjust the temperature to a cooler setting by pressing
the minus button to reduce the temperature. Set the Fan
Speed control to the highest setting.
Water drips from cabinet
into your house
The air conditioner is not properly
leveled. The air
conditioner
should slope slightly downward toward the
outside. Level the air conditioner to provide a downward
slope toward the outside to ensure proper drainage. See the
Installation Instructions.
NOTE: Do not drill a hole into the bottom of the metal base
and condensate
pan.
When your air conditioner
is operating normally, you may hear
sounds such as:
Droplets of water hitting the condenser, causing a pinging or
clicking sound. The water droplets help cool the condenser.
Air movement from the fan.
Clicks from the thermostat cycle.
Vibrations or noise due to poor wall or window construction.
A high-pitched
hum or pulsating noise caused by the modern
high-efficiency
compressor
cycling on and off.
ASSISTANCE OR SERVICE
Before calling for assistance or service, please check
"Troubleshooting."
It may save you the cost of a service call. If
you still need help, follow the instructions
below.
When calling, please know the purchase date and the complete
model and serial number of your appliance. This information will
help us to better respond to your request.
If you need replacement
parts
If you need to order replacement
parts, we recommend
that you
use only factory-specified
replacement
parts. Factory-specified
replacement
parts will fit right and work right because they are
made with the same precision used to build every new appliance.
To locate factory-specified
replacement parts in your area, call
your nearest designated service center.
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

W7wcc105xb0W7wcc128xb0

Table of Contents