Important
Safety
Instructions
ooooooooooooooooooooooo
Electrical
Shock
Hazard
1. Plug unit only into grounded
electrical outlet.
2. Do not use an extension cord or plug adapter with this unit,
3. Do not operate unit with front removed.
Failure
to follow
the
above
precautions
could
result
in
electrical
shock,
fire or personal
injury.
If the air conditioner
has a serial
plate
rating
of 115 volts
and up to
and
including
7.S amps
the unit
may
be on a fuse or circuit
breaker
with
other
devices.
However,
the maximum
amps
of all devices
on
tbat
fuse
or circuit
breaker
can
not exceed
tbe amps
of tbe f!lse or
circuit
breaker.
If the air conditioner
has a serial plate
rating
ofllS
volts
and greater
than
7.5 amps
it must
have
its own
fuse or circuit
breaker,
and
no
other
device
or unit should
be operated
on that fuse or circuit
breaker.
If the air conditioner
has a serial
plate
rating
of 230 volts
it must
have
its own
fuse
or circuit
breaker,
and
no other
device
or unit
should
be operated
on that fuse or circuit
breaker.
The
location
of the
serial
plate
that
applies
to this
inodel
can
be
found
on the front
page
of this
manual.
Notice:
Do not
operate
this
air
conditioner
without
proper
time
delay
cir-
cuit
protection,
Refer
to
serial
plate
for proper
power
supply
requirements,
RECOMMENDED
CIRCUIT
WIRE
SIZES
(As iustalled
per buildi_l,,¢ co&)
PROTECTOR
SIZE
WIRE
GAUGE
1S AMP
#14 MINIMUM
20 AMP
#12 MINIMUM
30 AMP
# 10 MINIMUM
@©©@
115V
230V
230V
230V
15.4
15.4
20A
30A
Hgo A
Expamled
Polystyrene
gray/white
foam)
similar
to yourairconditioueT:
Product
Damage:
Do not
cut, alter
or remove
any
of the
expand-
ed
polystyrene
(gray/white
foam)
inside
this
air
conditioner
(Fig. AI. THE GREY FOAM
IS PART OF THE UNIT, NOT
PACKING
MATERIAL.
For Your
Safety:
Do not
store
or use gasoline
or other
flaInmable
vapors
and
liquids
in the vicinity
of this or any other
appliance.
The
fumes
can create
a fire hazard
or explosion.
Before
Getting
Started
o°°
Electrical
Requfyements
Si1_?le outlet
groundin,,q wall
Important
Grounding
Requirements
1. Air conditioner
has a three-prong
grounding
plug
on
power
supply
cord,
which
must
be
plugged
into
prop-
erly
grounded
three-prong
wall
receptacle
for
your
pro-
tection
against
possible
shock
hazard,
For
models
up
to
and
including
7,5
amperes
use
grounding
type
wall
receptacle
to
match
cord
plug
(Fig.
B).
2.
For
models
above
7,5
amperes
use
single
outlet
ground-
ing
type
wall
receptacle
to
match
cord
plug
(Fig.
C).
Caution:
We
recommend
that
a
qualified
electrician
install
unit
in
accordance
with
the
National
Electrical
Code
and
local
codes
and
ordinances.
Caution:
Use copper
conductors
only.
°°°°°°°°°°°°°°°°°°°°°°°°°°O
Window
Requirements
Your
new
room
air conditioner
is factory
prepared
for easy
installation
in a horizontal
sliding
or casement
type win-
dow with
a minimum
width
of 15 1/2 inches.
Unit
will
fit a
42 inch high window
opening
as received
from factory.
Caution: Do not block air circulation to outside louvers
of cabinet.
Tools
Needed
•
Blade-typescrew&iverj_
•
Ruler
(__)
°"
•
Drill
_
•
Awl
_C/_
•
Knife
,/
•
Pencil
•
1/Sinch
&illbit
/_
X/
•
Level
Need help?
Do you have a question about the 23-11-2214N-002 and is the answer not in the manual?