Nortel 1000 Fundamentals page 426

Ip trunk fundamentals
Table of Contents

Advertisement

426 Maintenance
If self-tests T:10-T:17 fail, the display contains the failure message for three
seconds and the ITG-Pentium 24-port trunk card goes on to the next test. If
more than one test fails, the message displayed indicates the last failure.
Table 70
ITG-Pentium 24-port trunk card faceplate maintenance display message
summary
Normal
Code
T:00
T:01
T:02
T:03
T:04
T:05
T:06
T:07
T:08
T:09
T:10
T:11
T:12
T:13
T:14
T:15
T:16
T:17
T:18
PT:0
PT:1
T:19
Copyright © 2007, Nortel Networks
.
Fault
Code
Description
F:00
Initialization
F:01
Testing Internal RAM
F:02
Testing ALU
F:03
Testing address modes
F:04
Testing Boot ROM
F:05
Testing timers
F:06
Testing watchdog
F:07
Testing external RAM
F:08
Testing Host DPRAM
F:09
Testing DS30 DPRAM
F:10
Testing for presence of security device. The
ITG-Pentium 24-port trunk card has no security device.
For the ITG-Pentium 24-port trunk card, a momentary
display of F:10 is normal.
F:11
Testing flash memory
F:12
Programming PCI FPGA
F:13
Programming DS30 FPGA
F:14
Programming CEMUX FPGA
F:15
Programming DSP FPGA
F:16
Testing CEMUX interface
F;17
Testing EEPROM
F:18
Booting host, waiting for response with self-test
information
PF:0
Pentium module suspend signal OK
PF:1
Pentium module powered OK
If the displays this message, check that the Pentium
module is fully seated in the motherboard socket.
Waiting for application startup message from host
Nortel Communication Server 1000
IP Trunk Fundamentals
NN43001-563 02.01 Standard
Release 5.5 21 December 2007

Advertisement